28
1300905-W2-A
2
Identify which is the hot inlet to the mixing valve body, and align the cartridge assembly
accordingly.
Note!
There is a 'H' and 'C' marked on the cartridge. Make sure that the 'H' aligns with the hot
inlet and that the 'C' aligns with the cold inlet.
Align the cartridge guides with the slots in the body and carefully push the cartridge assembly
back into the body, checking that the 2 cartridge inlet port seals remain in place.
Install the six screws and tighten.
Fit the temperature indicating ring.
Turn the isolation screw on the isolator valves through 90
o
to restore the water supplies to
the valve and check for any leaks.
Before fitting the hub, the temperature will need re-setting; refer to
COMMISSIONING
.
Re-fit the temperature knob.