LLDP (Service IP info)
Data transmitted through the LLDP protocol can be accessed in two ways:
• OnTransmissions every 60 seconds
• SingleTransmitted once only when unit is rebooted
See "IPv4 address - Local ... Unknown IP address" for description of the data transmitted through
the LLDP protocol.
Link authorization guard
User data flow to the remote unit can be established dependent on remote station authorization.
The authorization is secured by using SSH keys. For info about unit authorization see user manual,
section
CLI > Configuration with CLI > Remote unit authorization
• Disabled — User data flow through the Air channel is enabled even if the remote unit is not au-
thorized.
• Enabled — User data flow through the Air channel is enabled only if the remote unit is authorized.
The "Link authorization guard" parameter value of the remote unit is ignored.
Speed guard
The speed guard controls automatically the Egress data rate shaping according to available capacity
of the Air channel. The Air channel capacity check and the Egress shaping adjustment takes place
approx. once per 50 ms.
RAy3 Microwave Link – © RACOM s.r.o.
96
Configuration
Summary of Contents for RAy3-11