5
归零校正
须按2秒以上(功能键)
0Kg CALIBRATION
PUSH MORE THAN 2 SEC.
以下情况须要做归零校正
:
1.
本装置安装完成后。
2.
尺寸有异常不稳定时。
3.
感应轮在无负载的状态(移开感应轮上的松紧带),在任何一段工程中,
送料值在
980
~
999
之间的其中一值,(灵敏度必须设定在
99
),而驱动轮
未停止转动时。
Always correct the calibration after the following instances :
1.After installation.
2.If the device is feeding irregularly.
3.If the driven roller can not stop. In any section.
The driven roller must stop when the tension value to be adjusted
between 980-990 and the sensitivity is set at 99 after remove the
elastic tape from the sensor bar (Make sure nothing Contact with Sensor Bar).
归零校正时应移开感应轮之松紧带(如下图
※)
Please remove the elastic tape before calibration (Refer to the following figure).
操作说明
:
OPERATION GUIDE
:
感应轮
SENSOR
松紧带移开感应轮
※
Remove the elastic tape from the sensor bar
驱动轮
Driven Roller
注意:
Notice
:
如果准归零后,
其数值不介于
10
~
90
之间时,
即表示装置有
问题,需要检
修。
If the value is
Not between
10~90 after
Regular
Calibration.
The device
Needs to be
REPAIRED.
1
FUNCTION
功
能
0 Kgrams Setting
-
0 Kgrams Default
0 Kgrams Setting
0 Kgrams Default
0050
0050
0050