Stopping
production
Stopping
pH
regulation
A4
Yes
No
Cell problem.
•
Check that the cell is not scaled.
•
Inspect and adjust if necessary the
inversion frequency of the current
supplying the cell.
•
Check
that
the
electrical
connections to the terminals of the
cell are sufficiently tight and not
oxidised.
•
Check that the cell's power cable is
in good condition.
•
Check that the cell's power cable
connector is correctly connected to
the electronics unit.
•
As a last resort, replace the cell.
A7
No
Yes
pH corrector container empty.
Replace the pH corrector container.
AL
No
Yes
Series of 5 unsuccessful attempts to
correct the pH.
•
Ensure the pH corrector container is
not empty.
•
Carry out a manual injection.
•
Check the condition of the filter
with
ballast
and
injection
connector.
•
Check :
-
Setting the pH setpoint.
-
The specification of the type of pH
corrector.
-
The
specification
of
the
concentration of the pH corrector.
-
The specification of the volume of
the pool.
•
Carry out a calibration of the pH
probe.
CA
No
Yes
pH probe incorrectly calibrated.
Carry out a calibration of the pH
probe, by pressing and holding
OK
.
3.9.
Further information
Menu
Sub-menu
Successive display
Meaning
Sw
cm
2 digits, then 2 other digits
Control board program
pw
2 digits, then 2 other digits
Power card program