Heating mode:
If the heater is receiving enough flow and set point value is greater than
the pool water temperature ‘HEATER DELAY’ will be shown on the display
(Fig.11).
It will appear for two minutes before the device commences the heating
process. The delay time is required to prevent a cycling effect due to air
pockets trapped in the pipe work system or any water fluctuations.
The combination of the delay time and flow switch sensor is ensuring that
your device always receives enough flow and the heating element is fully
submerged. This will extend the life expectancy of the components and
the product.
After two minutes, the controller will switch on the heating output, RED
LIGHT will come ON and the display will show current water temperature
(Fig.12).
Fig 11.
The heater will stay on until set temperature point is reached. When
reached the heater will maintain pool temperature within 0.5°C differential.
Fig 12.
1
2
ENGL
IS
H