background image

 

-6-axis movement & position 
+ 3 acceleration ch 3 
angular rate channels 

No. of buttons 

2 functional buttons 
1 service button - on/off 

Vibration 

Yes 

Lights system information 

 

Status connect, status battery 

Made in 

 

 Poland, EU 

 

Raccoon.Recovery Sensors: 

 
Weight 

30g 

Size 

58X42X15mm 

Storage temperature 

−20 °C  - +60 °C 

Exploitation temperature 

 

+5°C - +35°C 

Power consumption 

 

DC 5V 350mA (charging state) 

Battery type

Internal lithium-polymer battery  

Battery capacity

250mA 

Voltage

DC 3.7 V 

Data transfer 

 

Bluetooth 4.0 BLE 

Sample rate 

100 frame per sec 

Sensors 

 

Accelerometer, gyroscope 
-6-axis movement & position 
+ 3 acceleration ch 3 
angular rate channels 

No. of buttons 

1 service button - on/off 

Vibration 

Yes 

Lights system information 

Status connect, status battery 

Made in 

 

Poland, EU 

 

 

Information!​

 Controller/sensor operation is possible with Raccoon receiver only.  

 
Raccoon.Recovery Receiver: 

 

 
Weight                                        12g 
Size                                                         58X23.5X12.5mm 
Storage temperature                           −20 °C  - +60 °C 
Exploitation temperature                    +5°C - +35°C 
Power consumption                            DC  5V 120mA (working state) 
Data transfer                                        Bluetooth 4.0 BLE 
Sample rate                                          100 frame per sec 
Lights system information                Status connect 
Interface                                               USB 2.0 
Made in                                                 Poland, EU 

 

Summary of Contents for Raccoon.Recovery

Page 1: ...both in the rehabilitation centre and in any other location convenient for the user telerehabilitation including at home settings A Specialist and or another representative of the Clinic will be able...

Page 2: ...n and a unique personal password generated by the Platform The Hardware connects to a PC via Bluetooth with the help of receiver and transmits data to the PC and then to the Platform via the Internet...

Page 3: ...blurry vision muscle twitching any involuntary movements and or convulsions Warning Use with upper limbs prosthesis is not foreseen Devices of the Hardware Solution Requires PC with USB 2 0 or compat...

Page 4: ...charged and it is recommended to charge it in this case vibro will not work 4 4 Flashing Red indicates that the Device need charging In this case the operation of the Device will be impossible and it...

Page 5: ...ndling and charging instructions and carefully follow them Always dispose of used batteries in accordance with local laws and regulations Instruction how to start working with the Devices 1 A link to...

Page 6: ...n and wait for the installation to complete 8 Enter into the program using the role username and password that were emailed to you earlier 9 Turn on the Device and wait till connects to the receiver 1...

Page 7: ...fire and burns Warning Never attempt to open crush heat or burn a battery Warning Do not leave the battery charging for a prolonged period of time when the Device is not in use Warning Do not operate...

Page 8: ...om nylon polypropylene or gauze or cloth If the buttons need to be removed to remove dirt the buttons must be removed Pic 4 Pic 4 The way the buttons must be removed for cleaning 3 Wipe the surface of...

Page 9: ...contact of the Devices with water as this may cause a malfunction Warning Wipe the Devices from the outside with a damp cloth making sure that moisture does not get inside the Devices To clean the st...

Page 10: ...uman health and the ecology Specification Raccoon Recovery Controller Weight 90g Size 135X75X42 mm Storage temperature 20 C 60 C Exploitation temperature 5 C 35 C Power consumption DC 5V 500mA chargin...

Page 11: ...transfer Bluetooth 4 0 BLE Sample rate 100 frame per sec Sensors Accelerometer gyroscope 6 axis movement position 3 acceleration channels 3 angular rate channels No of buttons 1 service button on off...

Page 12: ...er to a different port or to computer laptop directly 5 The Device does not connect to the receiver 5 1 Make sure that the indication flashes blue on both the Device and the receiver 5 2 Make sure tha...

Page 13: ...of the following symptoms while working in front of the monitor loss of consciousness loss of orientation blurry vision muscle twitching any involuntary movements and or convulsions 6 Warning Use with...

Page 14: ...moistened cloth Allow Device to dry after cleaning or disinfection Do not use while still wet 37 Warning Before turning on or charging the Controller make sure that its surface is completely dry 38 Wa...

Page 15: ...e or modify the Devices Warning Transport the Devices in the original packaging by the manufacturer only If you have concerns that the device requires maintenance contact your Specialist or manufactur...

Page 16: ...Effective Date 03 03 2020 Controller REF 2000 1000 Arm Sensor REF 2000 0300 Raccoon Recovery Version 1 0 code REF 2000 1305...