1258 User Manual
Operating Instructions 4-14
Racal Instruments
©
2005
Configuration
Commands and
Queries
The CONFigure command and query allows the Diagnostic,
MultiConnect, AutoUpdate, and PowerUp modes to be configured
or their state determined.
Syntax:
CONFigure:DIAGnostic - set diagnostic mode
CONFigure:DIAGnostic? - return current diagnostic mode
CONFigure:MULTiconnect
-
sets multi-connect mode
CONFigure:MULTiconnect? - return current multi-connect mode
CONFigure:AUTOupdate - sets auto-update mode
CONFigure:AUTOupdate? - return current auto-update mode
CONFigure:POWErup - sets power-up mode
0 = all switches open and default operational modes
1 = Current configuration
2 = Last configuration at time power was removed
CONFigure:POWErup? - return current power-up mode
Examples:
CONFigure:DIAGnostic(1)- enable diagnostic mode
CONFigure:DIAGnostic? - returns '1' if diagnostic mode
is enabled, otherwise it returns '0'
CONFigure:MULTiconnect(0) - disable multi-connect
mode (one output per input)
CONFigure:MULTiconnect? -
returns '1' if multi-
connect mode is enabled, otherwise it
returns '0'
CONFigure:AUTOupdate(1) -
enable auto-update
(automatically performs UPDATE
operation on OPEN and CLOSE
commands
CONFigure:AUTOupdate? - returns '1' if auto-update
mode is enabled, otherwise it returns
'0'
CONFigure:POWErup(2)- set power-up mode to
configuration at time power removed.
CONFigure:POWErup? - returns value depending on current
mode