Pump does not reach the max pressure

Possible causes: Pump sucking air; Incorrect nozzle; Diameter of garden hose is too small; Water
supply is restricted or supply is too low pressure. 
Check all the above.

• 

The output pressure varies and is not constant

Possible Causes: Pump sucking air; Diameter of garden hose is too small; Water supply is
restricted or supply is too low pressure, nozzle is damaged, or Blocked
Check all the above.
Note: clean dirt from nozzle (refer to nozzle cleaning instructions).

• 

The motor stops suddenly

Possible Causes: Thermal safety switch has tripped due to the overheating. If the pressure
washer overheats the pressure washer will switch off automatically. If this happens switch off the
pressure washer and let the motor cool down for 15 minutes before switching on again.One
Common reason for overheating is low water inlet pressure. To check this you should be able to
fill a 10 litre bucket in 1 minute.

• 

Pump is noisy

Possible Causes: Air intake damaged or blocked; Bearings are worn out; Supply water at extreme
temperature .
Check all the above.

• 

Water leaking from the pump

Cause: Loose fitting; Missing/worn rubber washer.
Solution: Check and replace.

• 

Lance Trigger will not operate

Possible causes: Safety catch on.
Check and ensure safety catch is released.

Plug fitting

Note: If a moulded plug is fitted and has to be removed take great care in disposing of the plug
and severed cable, it must be destroyed to prevent engaging into a socket. If the supply cord is
damaged it must be replaced by a service agent or similarly qualified person if order to avoid
hazard. Your pressure washer is supplied with a fitted plug, however if you should need to fit a
new plug follow the instruction below. If in doubt consult a qualified electrician.

IMPORTANT

The wires in the mains lead are coloured in accordance with the following code:
Blue - Neutral Brown - Live
As the colours of the wires in the mains lead of this appliance may not correspond with the
coloured markings identifying the terminals
in your plug, proceed as follows:
The wire which is coloured blue must be
connected to the terminal which is marked
with N or coloured black.
The wire which is coloured brown must be
connected to the terminal which is marked
with the letter L or coloured red.
No connection is to be made to the earth
terminal of the plug.
If a 13 AMP (BS 1363/A) Plug is used, a
13 AMP Fuse must be fitted, or if any other
type of plug is used a 13AMP Fuse must be
fitted, either in the Plug or Adaptor, or on the
Distribution Board.

EC DECLARATION OF CONFORMITY

BLUE
(NEUTRAL)
N

OUTER
SLEEVE

 13 AMP
 FUSE

BROWN
(LIVE)
L

CABLE GRIP

EQUIPMENT: 

1800W Pressure Washer

MODEL NUMBER: 

RAC-HP021

EU REPRESENTATIVE: 

Hilka Pro Imports

This is to certify that the aforementioned equipment fully conforms to the protection 
requirements of the following EC Council Directives on the approximation of the 
laws of the member states relating to:

Applicable Directives:

And in consideration of the following standards:

Conformity assessment procedure followed: 

   

Annex C

Sound power level:

This declaration ceases to be valid should there be any modifications or changes to the 
equipment, outside the details in the Instruction Booklet, made by the user.

Name:   

R.J. Satchell 

Position:             

Director

Date of issue: 

Nov 15th, 2005 

2000/14/EC

89/336/EEC

73/23/EEC
93/68/EEC

98/37/EC

EN 50366:2003 
EN 55014-1:2000

 / + A1:2001 + A2:2002

EN 55014-2:1997

 / + A1:2001

EN 61000-3-2:2000
EN 61000-3-3:1995

 / + A1:2001 

EN 61000-3-11:2000
EN 60335-2-79:2004
EN 60335-1:2002

 / + A11:2004 + A1:2004

EN ISO3744:1995

Measured 88.6dB 