![background image](http://html2.mh-extra.com/html/rabbit/fox-lp3500/fox-lp3500_user-manual_3120132076.webp)
70
Fox (LP3500)
4.5 Relay Output (LP3500 only)
A 10 ms low-to-high pulse sets the state of a relay. On power-up or
brdInit()
the relay contact will
go to the normally closed (NC) RESET contact.
PARAMETERS
relay
0 = the one relay
value
is a value used to connect the relay common contact:
0 = relay normally closed (NC or RESET) (Parallel Port PG5)
1 = relay normally open (NO or SET) (Parallel Port PG4)
RETURN VALUE
0 if successful
-1 if the normal power source is not available
int relayOut(int relay, int value)