background image

INSTRUCTIONS

EZPAN® HE INSTALLATION

RAB Lighting is committed to creating high-quality, aff ordable, well-designed and energy-effi  cient LED lighting and controls that make it easy for electricians to install

and end users to save energy. We’d love to hear your comments. Please call the Marketing Department at 888-RAB-1000 or email: [email protected]

IMPORTANT

READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.

RAB fi xtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper grounding is 
required for safety. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON 
FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED. 

WARNING: Make certain power is OFF before installing or maintaining fi xture. No user serviceable parts inside. 
CAUTION: For proper weatherproof function all gaskets must be seated properly and all screws inserted and tightened 
fi rmly. Apply weatherproof silicone sealant around the edge of the ceiling mounting box and/or junction box. This is 
especially important with an uneven ceiling surface. Silicone all plugs and unused conduit entries.

Fig: 1

Fig: 3

Fig: 4

Fig: 2

RECESSED CEILING MOUNTING

The fi xture is suitable only for 

INDOOR RECESSED CEILING 

application. Above ceiling access required.
To mount in an insulated or non-insulated ceiling - 9/16” or 15/16” 
exposed Flat Tee Grid Ceiling follow the steps below. 
1.  Firmly bend the pre-installed 

Grid Clips

 (up and out as shown) 

Fig. 1

2. 

Rotate and slide the 

Fixture

 as required to fi t through the    

Tee-Grid Bar

 and place it as indicated by the directional arrow 

as shown in 

Fig. 2

. Secure the 

Fixture

 to the 

Tee-Grid Bar

3.  Support wires are required by Installation Codes. Support the 

Fixture

 to the building structure by 

Support Wires

(supplied by 

others)

 through the 

Grid Clip Hole

 as shown in 

Fig. 3

.

4.  Make sure that the orientation of the 

Splice Box

 and 

Access 

Plate

 faces an accessible tile to make electrical splices. 

5. 

Loosen 

Access Plate Screw

 and remove the 

Access Plate

Knock out appropriate 

Conduit Knockouts

 on the 

Access Plate

to route input conduit. Use appropriate conduit connectors as 
required by code as shown in 

Fig. 4

.

6.  Connect wires as shown in wiring diagram. Push all wires 

back into the 

Splice Box

. Use appropriate UL approved wire 

connectors as required by code to complete wiring. Be careful 
not to pinch wires. 

WARNING:

To prevent wiring damage or 

abrasion, do not expose wiring to edges of sheet metal or other 

sharp objects. 

7. 

Replace 

Access Plate

 and tighten 

Access Plate Screw

.

EZPAN HE 1X4

EZPAN HE 2X2

EZPAN HE 2X4

Access Plate

Conduit

Knockouts

Fixture

Grid Clip

Tee-Grid 

Bar

Access 

Plate Screw

Splice Box

Grid Clip 

Hole

Grid 

Clip

Power

Feed

Fixture

Firmly bend 

Grid 

Clips

up and out

Support Wire

(supplied by others)