background image

TALLPACK INSTALLATION INSTRUCTIONS

(continued)

MOUNTING

Bottom Conduit Mounting:
1.  With front housing and refl ector off, knockout
 

the bottom conduit hole in the rear housing.

2.  Pull service wires through the conduit opening and
 

make connection as indicated under Wiring section.

3.  Replace the refl ector and refractor cover.
4.  Attach to wall box per “Odd-sized Box Mounting”,
 

instructions #2 & 3 on previous page.

WIRING

Use supply wire rated for 90°C.

Caution: Check that voltage is compatible with fi xture ballast.
1.  Connect the black fi xture lead to the black supply lead.
2.  Connect the white fi xture lead to the white supply lead.
3.  Connect supply ground wire to fi xture ground screw.

RE-LAMPING

Caution: Prior to installing, check that the lamp is of the proper type and wattage. Observe lamp manufacturers 
recommendations on lamp operation, ballast type and burning positions. Disconnect power. Make sure fi xture and
lamp are cool enough to touch.

REPLACEMENT LAMPS

High Pressure Sodium 

ANSI   

 

 

Fluorescent

Wattage 

Catalog # 

Code   

 

 

Wattage 

Catalog #

  35 

LHPS35 

S76 

28 

LCFL28

  50 

LHPS50 

S68 

42 

LCFL42

  70 

LHPS70 

S62

CLEANING

Caution: 

Be sure fi xture is cool enough to touch. Be sure power is off.

Clean refl ector and refractor with a cloth moistened with non abrasive, non fl ammable glass cleaning solution.

TROUBLE SHOOTING CHECKLIST

Check that:

1.  Proper lamp is installed. Lamp is not faulty.
2.  Line voltage at the fi xture is proper. 

EASY INSTALLATION & PRODUCT HELP

Fax Back  

Tech Help Line 

 

Website             

     e-mail

888-RAB-1236 

8AM – 5PM ET Mon. – Fri. 

www.rabweb.com       [email protected]

 

 

 

888-RAB-1000

 

 

 

 

 

 

Over 28 warehouses nationwide!

1.  Remove front refractor following instructions
 

under Mounting section.

2.  Remove old lamp.  

3.  Place lamp into lamp socket securely until it is  

 

 

fi rmly seated.

4.  Replace front refractor.

Wattage 

Catalog # 

Code   

 

 

Wattage 

Catalog #

Wattage 

Catalog # 

Code   

 

 

Wattage 

Catalog #

Wattage 

Catalog # 

Code   

 

 

Wattage 

Catalog #

Wattage 

Catalog # 

Code   

 

 

Wattage 

Catalog #

Wattage 

Catalog # 

Code   

 

 

Wattage 

Catalog #

3.  Fixture is wired properly.
4.  Fixture is grounded properly.

THESE INSTRUCTIONS DO NOT COVER ALL 
DETAILS OR VARIATIONS IN EQUIPMENT, 
NOR DO THEY PROVIDE FOR EVERY POSSIBLE 
CONTINGENCY TO BE MET IN CONNECTION WITH 
INSTALLATION, OPERATION OR MAINTENANCE.

©2005 RAB Lighting, Inc.

Rear Housing

Conduit Knockout

Photocell
(not applicable 
for NPC fi xtures)

for NPC fi xtures)