4 Installation
!
ATTENTION
— The device emits RF energy in the ISM (Industrial, Scientific, Medical) band. Make sure
that all medical devices used in proximity to this device meet appropriate susceptibility specifications for
this type of RF energy.
!
ATTENTION
— The device is recommended for use in industrial environments. It is mandatory to employ
a functional ground connection to comply with safety requirements.
!
ATTENTION
— The device is not supposed to be disassembled. Do not break the seal!
4.1 General
TIP
— Please consider the general behavior and physics of the wireless channel when deploying devices.
Placement of devices may need to be adjusted during functional testing.
4.2 Mechanical Installation
Figure 4I: Dimensions are in millimeters (mm)
Screw the antenna to the device’s SMA connector.
Note: antenna is excluded from diagram
4.2.1 DIN Rail Mounting
Figure 4II: DIN rail mounting
1. Use the selftapping screws provided
to attach the device to DIN rail. Place
the screws through the small DIN rail
adapter plates and screw into device
in their designated position.
2. Place the device nowfixed adapter
on the top edge of DIN rail.
3. Push the device downwards so it
snaps into place.
TIP
— To release device from DIN rail, push the device downwards while pulling outwards.