R.V.R. ELETTRONICA S.r.l. (BO)
Pag. 81
VJ3000 - Technical and Maintenance Manual
requirements of the user.
See SETUP 5 before carrying out this procedure.
1)
Ensure that the R.F. probe fitted to the directional coupler is
correctly orientated. Increase the output power for an external
reading of 3000 W.
2)
Adjust trimmer R66 on the protection card to obtain the same reading
on the VJ3000 meter (9 Fig.3) as on the external wattmeter.
3)
Reduce power to 1500W (equivalent to a 3dB drop).
4)
Connect an Ohmeter between pin 9 of the Telemetry connector
(SETUP 9) and ground.
5)
Adjust trimmer R158 to cause the Ohmeter to read open circuit. This
will establish the Power Good threshold.
Summary of Contents for VJ3000
Page 1: ...R V R ELETTRONICA S r l BO Pag 51 VJ3000 Technical and Maintenance Manual 1 2 3 4 6 5 FIG 10...
Page 13: ...R V R ELETTRONICA S r l BO Pag 63 VJ3000 Technical and Maintenance Manual SETUP 1...
Page 14: ...R V R ELETTRONICA S r l BO Pag 64 VJ3000 Technical and Maintenance Manual SETUP 2...
Page 15: ...R V R ELETTRONICA S r l BO Pag 65 VJ3000 Technical and Maintenance Manual SETUP 3...
Page 32: ...R V R ELETTRONICA S r l BO Pag 82 VJ3000 Technical and Maintenance Manual SETUP 4...
Page 33: ...R V R ELETTRONICA S r l BO Pag 83 VJ3000 Technical and Maintenance Manual SETUP 5...
Page 34: ...R V R ELETTRONICA S r l BO Pag 84 VJ3000 Technical and Maintenance Manual SETUP 6...
Page 35: ...R V R ELETTRONICA S r l BO Pag 85 VJ3000 Technical and Maintenance Manual SETUP 7...
Page 36: ...R V R ELETTRONICA S r l BO Pag 86 VJ3000 Technical and Maintenance Manual SETUP 8...
Page 37: ...R V R ELETTRONICA S r l BO Pag 87 VJ3000 Technical and Maintenance Manual SETUP 9...