TX05KSS/61D082B & TX05KSS/61S082
7
/ 20
User Manual
Rev. 1.0 - 28/10/16
Connect the overall power cord of machine. The cable can be slid through the
cable gland located on the back, or on the roof, of the machine and conductors
must be attached to the general disconnecting switch terminals.
Note:
The connection of machine to power supply is done by fixing a multi-pole
cable with exposed terminals to a terminal board. Make sure, with no possibility
of error, that the cable is not under tension when you connect it to the machine.
WARNING: Is highly recommended to don’t turn on the machine without first
having connected the RF output to antenna or dummy load!
If you have a dummy load capable to dissipate the RF power generated by the
transmitter, it is advisable to carry out first tests by linking to it rather than to the
transmission antenna.
If transmitter require a single-phase power with F (black or brown or grey) + N
F (black or brown or grey) + N
(blue) + GND (green yellow), keep in mind this requirement to connect to your
, keep in mind this requirement to connect to your
distribution board.
L N PE
If transmitter require three-phase power with 3F (black, brown and grey) + N
3F (black, brown and grey) + N
(blue) + GND (green yellow), keep in mind this requirement to connect to your
, keep in mind this requirement to connect to your
distribution board.
R S T N PE
Note:
the mains must be equipped with adequate earth connection properly
connected to the equipment. This is a pre-requisite for ensuring operator safety
and correct operation.