14
/ 30
User Manual
Rev. 1.1 - 06/07/20
TEX1000LIGHT
25% output power
1/4 bar
≅
250W in uscita
(mod.TEX1000LIGHT)
The bottom line provides instantaneous power reading (in this example 997W);
press button to increase level, press to decrease it. When you have achieved
the desired level, press
ENTER
to confirm and exit the
default menu
. Please
note that the setting is stored automatically; in other words, if you press
ESC
or
do not press any keys before the preset time times out, the latest power level set
will be retained.
NOTE: This feature prevents the machine from delivering maximum power as
soon as output is enabled from menu 4, or in the event the machine is already
set to
ON
and energised.
2) Ensure that machine is not in a locked-out state. Press the
ESC
key to call up
the selection screen (Menu 3). Highlight
Fnc
and press
ENTER
to confirm and
access the appropriate menu (menu 4).
If
LOC
is set to
REMOTE
(machine remote control), move cursor to
LOC
and
press
ENTER
; label will change to
LOCAL
, i.e. local control operation mode.
In the same menu, ensure that power limiting is disabled: if
PWR
is set to
OFF
,
i.e. power output is disabled, move cursor to
PWR
. Press
ENTER
and label
will switch to
ON
, i.e. power output enabled.
Press
ESC
twice to go back to the
default menu
(menu 1).
3) Fine tune power setting from menu 2 (see description of item 1b) until achieving
the desired value.
WARNING: Machine is capable of delivering more than rated output power
(1000 W); however, never exceed the specified power rating.
NOTE: If power is set to 0 W in the
Power Setup Menu
, the INTERLOCK OUT
contact is activated and any external appliances connected to it are immediately
inhibited.
Next, you can review all operating parameters of the machine through the
management firmware.
Normally, the machine can run unattended. Any alarm condition is handled
automatically by the safety system or is signalled by the LED indicators on the
panel or by display messages.
NOTE: Standard factory settings are: output power set to upper limit (unless
otherwise specified by customer) and
OFF
.
Summary of Contents for TEX1000LIGHT
Page 1: ...TEX1000LIGHT TEX1000LIGHT USER MANUAL VOLUME1 Manufactured by R V R ELETTRONICA Italy ...
Page 6: ...iv User Manual Rev 1 1 06 07 20 TEX1000LIGHT This page was intentionally left blank ...
Page 36: ...30 30 User Manual Rev 1 1 06 07 20 TEX1000LIGHT This page was intentionally left blank ...