10
/ 30
User Manual
Rev. 1.1 - 06/07/20
TEX1000LIGHT
Provide for the following (applicable to operating tests and putting into service):
√
Single-phase 230 (-15% / +10%) Vac mains power supply, with adequate earth
connection.
√
For operating tests only: dummy load with 50 Ohm impedance and adequate
capacity (1000W for
TEX1000LIGHT
).
√
Connection cable kit including:
• Mains power cable.
• Coaxial cable with BNC connectors for interlock signal connection between
exciter and amplifier.
• RF cable for output to load / antenna (50 Ohm coaxial cable with standard 7/16”
connector).
• Audio cables between transmitter and audio sources.
5.1.2 Connections
Connect the RF output of the transmitter to the antenna cable or a dummy load
capable of dissipating exciter output power. To begin with, set exciter to minimum
output power and switch it off.
Connect the transmitter INTERLOCK IN input to the matching INTERLOCK OUT
output fitted on R.V.R. Elettronica equipment to act as hybrid couplers. If your
equipment is a different brand, identify an equivalent output
.
WARNING: Electric shock hazard! Never handle the RF output connector
when the equipment is powered on and no load is connected. Injury or death
may result.
Ensure that the
POWER
switch on the front panel is set to “
OFF
”.
Connect the mains power cable to the MAINS connector on the rear panel.
Note :
The mains must be equipped with adequate ground connection properly
connected to the machine. This is a pre-requisite for ensuring operator safety and
correct operation.
5.2 First power-on and setup
Perform this procedure upon first power-up and each time you make changes to
the configuration of the transmitter this component is integrated into.
Note
: Standard factory settings are RF output power off (
Pwr OFF
) and regulated
output power set to upper limit (unless otherwise specified by customer).