![background image](http://html.mh-extra.com/html/r-v-r-elettronica/ptx-dds/ptx-dds_user-manual_775401044.webp)
40 / 54
User Manual
Rev. 1.2 - 24/01/11
PTX-DDS
7.4.3.11 Alarms setting submenu (
AlSet
)
This menu provides the alarm setting of the exciter.
| |FWD :00% 000s| |
| |RFL :00% 000s| |
| |Audio :00kHz 000s| |
| |Mains : 000s| |
| | | |
| |ExtFWD:00% 000s| |
| |ExtRFL:00% 000s| |
| |
Admin
---[Exit]---|
|
Figure 7.28
FWD
Selection of the alarm activation level in case of forward power lack
expressed in percentage. The adjustment of the level is available
in step of 1 % from 0 (alarm disabled) to 99 %.
RFL
Selection of the alarm activation level in case of reflected power
lack expressed in percentage. The adjustment of the level is
available in step of 1 % from 0 (alarm disabled) to 99 %.
Audio
Selection of the alarm activation level in case of audio lack
expressed in percentage. The adjustment of the level is available
in step of 1 % from 0 (alarm disabled) to 99 %.
Mains
Selection of the alarm activation time in case of mains power lack
expressed in seconds. The adjustment of the value is available
step of 1 s from 0 to 240 s.
ExtFWD
Selection of the alarm activation level in case of external forward
power lack expressed in percentage. The adjustment of the level
is available in step of 1 % from 0 (alarm disabled) to 99 %.
ExtRFl
Selection of the alarm activation level in case of external reflected
power lack expressed in percentage. The adjustment of the level
is available in step of 1 % from 0 (alarm disabled) to 99 %.
s
Selection of the alarm activation time, referred to the several
entries, expressed in seconds. The adjustment of the value is
available in step of 1 s from 0 to 240 s.
In the following is shown the operating logic of an alarm:
The bar
shows the alarm activation time.
Alarm state
PRESENT
Alarm state
ABSENT
time
Alarm state time limit before the timer
exhaustion of the activation time: ANY
ALARM IS NOT GENERATES and the
timer is reload to the starting value.
Timer time limit of alarm activation with
alarm state still persistent: ALARM IS
GENERATE