background image

PJ2000M-C, PJ2500M-C & PJ3000M-C

2 / 40

User Manual

Rev. 1.5 - 09/10/09

R.V.R. is never responsible for damage or loss), until 

the package reaches R.V.R. premises. For this reason, 

we suggest you to insure the goods for the whole value. 

Shipment  must  be  effected  C.I.F.  (PREPAID)  to  the 

address specified by R.V.R.’s service manager on the 

authorization

 

DO  NOT  RETURN  UNITS  WITHOUT  OUR 

AUTHORIZATION AS THEY WILL BE REFUSED

4  Be  sure  to  enclose  a  written  technical  report  where 

mention  all  the  problems  found  and  a  copy  of  your 

original  invoice  establishing  the  starting  date  of  the 

warranty.

Replacement  and  warranty  parts  may  be  ordered  from 

the  following  address.  Be  sure  to  include  the  equipment 

model and serial number as well as part description and 

part number.

 

R.V.R. Elettronica SpA 

Via del Fonditore, 2/2c 

40138 BOLOGNA ITALY 

Tel. +39 051 6010506

 

3.  First Aid

The  personnel  employed  in  the  installation,  use  and 

maintenance of the device, shall be familiar with theory and 

practice of first aid.

 

3.1  Treatment of electrical shocks

 

3.1.1  If the victim is not responsive

Follow the A-B-C’s of basic life support.

• 

Place  victim  flat  on  his  backon  a  hard 

surface.

• 

Open airway: lift up neck, push forehead back 
(

Figure 1

). 

Figure 1

• 

clear out mouth if necessary and observe for 

breathing

• 

if  not  breathing,  begin  artificial  breathing  

(

Figure 2

): tilt head, pinch nostrils, make airtight 

seal, four quick full breaths. Remember mouth 

to mouth resuscitation must be commenced as 

soon as possible.

Figure 2

• 

Check  carotid  pulse  (

Figure  3

);  if  pulse  is 

absent,  begin  artificial  circulation  (

Figure  4

depressing sternum (

Figure 5

).

           

      Figure 3

                    

Figure 4

Figure 5

• 

In case of only one rescuer, 15 compressions 

alternated to two breaths.

• 

If there are two rescuers, the rythm shall be of 

one brath each 5 compressions. 

• 

Do  not  interrupt  the  rythm  of  compressions 

when the second person is giving breath.

• 

Call for medical assistance as soon as  

possible.

 

3.1.2  If victim is responsive

• 

Keep them warm.

• 

Keep them as quiet as possible.

• 

Loosen  their  clothing (a  reclining  position  is 

recommended).

• 

Call for medical help as soon as possible.

 

3.2  Treatment of electrical Burns

 

3.2.1  Extensive burned and broken skin

• 

Cover  area  with  clean sheet or cloth.

• 

Do not break blisters, remove tissue, remove 

adhered particles of clothing, or apply any salve 

or ointment.

• 

Treat victim for shock as required.

• 

Arrange transportation to a hospital as quickly 

as possible.

• 

If  arms  or  legs  are  affected  keep  them 

elevated.

If  medical  help  will  not  be  available  within  an  hour  and 

the victim is conscious and not vomiting, give him a weak 

solution of salt and soda: 1 level teaspoonful of salt and 

1/2 level teaspoonful of baking soda to each quart of water 

(neither hot or cold).

Allow victim to sip slowly about 4 ounces (half a glass) over 

a period of 15 minutes. 

Discontinue fluid if vomiting occurs.

DO NOT give alcohol.

  3.2.2  Less severe burns

• 

Apply cool (not ice cold) compresses using the 

cleansed available cloth article.

• 

Do not break blisters, remove tissue, remove 

adhered particles of clothing, or apply salve or 

ointment.

• 

Apply clean dry dressing if necessary.

• 

Treat victim for shock as required.

• 

Arrange transportation to a hospital as quickly 

as possible.

• 

If  arms  or  legs  are  affected  keep  them 

elevated.

Summary of Contents for PJ1000M-C

Page 1: ...Manufactured by Italy PJ2000M C PJ2500M C PJ3000M C User Manual Volume 1...

Page 2: ...ng photocopying recording or by any informa tion storage and retrieval system without written permission of the copyright owner File Name PJ2000M C_PJ2500M C PJ3000M C_ING_1 5 indb Version 1 5 Date 09...

Page 3: ...3 5 Quick installation and operating reference 5 5 1 Preparation 5 5 2 Operation 8 5 3 Software 9 5 4 Protection System 15 6 External Description 17 6 1 PS Module Frontal Panel 17 6 2 PS module Rear...

Page 4: ...PJ2000M C PJ2500M C PJ3000M C ii User Manual Rev 1 5 09 01 09 This page was intentionally left blank...

Page 5: ...adequate measures Specifications and informations contained in this manual are furnished for information only and are subject to change at any time without notice and should not be construed as a comm...

Page 6: ...se is absent begin artificial circulation Figure 4 depressing sternum Figure 5 Figure 3 Figure 4 Figure 5 In case of only one rescuer 15 compressions alternated to two breaths If there are two rescuer...

Page 7: ...alled PS RF amplifier module called RF RF Module PS Module Figure 4 1 PJ3000M C PJ2500M C and PJ2000M C modules Subdividing it into two modules not only makes it easier to handle and assemble the ampl...

Page 8: ...RF IN TELEMETRY RS232 IIC INTERLOCK 50V AF AMP8 MOSFET BLF278 AF AMP8 MOSFET BLF278 AF AMP1 MOSFET BLF278 AF AMP1 MOSFET BLF278 AF AMP4 MOSFET BLF278 AF AMP4 MOSFET BLF278 AF AMP3 MOSFET BLF278 AF AMP...

Page 9: ...ngle phase 208 V 15 10 single phase 230 V 10 15 three phase 208 V 15 10 three phase 230 V 10 15 three phase 400 V 10 15 Suggestion Specify the type of power supply at order placement the machine will...

Page 10: ...9 10 09 Data connection by means of cable with DB37 connectors PS RF Interconnection Ground connection between each module chassis Power supply connection by means of cable coming out of the PS module...

Page 11: ...internal conductor floats when the amplifier works correctly on the contrary power is delivered and the internal conductor is closed to ground to halt the exciter Connect the RF output to the antenna...

Page 12: ...h the action of the Automatic Gain Control AGC is disabled 5 2 Operation After having plugged in the power supply socket at the back of the machine power on the amplifier via the switchboard The ON LE...

Page 13: ...livered from the amplifier reaches the desired value If back off is permanent to set the station s power at a level lower than the maximum rated output first disable the AGC by turning the RF PWR ADJ...

Page 14: ...ftware and hardware versions A few seconds later the main screenful is displayed indicating the forward and reflected power values Press the ESC key to view the selection screenful from which to acces...

Page 15: ...nector is set to ground so as to force the connected exciter to a stand by condition this takes place only if the exciter features the interlock option like those produced by RVR and if the associated...

Page 16: ...ul only two lines can be seen at a time use the UP and DOWN keys to scroll through it 5 3 4 Warning threshold setting menu As mentioned in the introduction the amplifier offers three settable warning...

Page 17: ...xample the alarm thresholds are as follows PwrGd1 2400 W 80 x 3000 W x mod PJ3000M C 2000 W 80 x 2500 W x mod PJ2500M C 1600 W 80 x 2000 W x mod PJ2000M C PwtGd2 1500 W 50 x 3000 W x mod PJ3000M C 125...

Page 18: ...t when the amplifier is connected in an RVR transmission system that envisages the use of this protocol Do not change it for any reason whatsoever The main menu may be displayed either in Digital mode...

Page 19: ...ated by X Y whereas the second one is indicated by Wait The third possibility is that the system does not trigger the protection conforming to a specific parameter this is indicated by Dis Disabled Wh...

Page 20: ...red LED when a fault occurs that stops the power amplifier This situation is signaled to the machine s main microcontroller as well and triggers a lock situation FAULT The LED FUSE BLOWN indicates th...

Page 21: ...mplifier is in local control mode 6 FOLDBACK Yellow LED indicating that the foldback function is active automatic reduction of the distributed power 7 CONTRAST Trimmer to regulate the contrast of the...

Page 22: ...us networking 6 INTERCONNECTION PS RF DB37 connector for interfacement with RF part 7 COM BUS DB15 connector for interfacement with other equipment 8 TELEMETRY DB25 telemetry connector 9 AUX OUT FUSE...

Page 23: ...erlock 6 Set 4 7 GND GND 8 On Command 9 Set 1 10 WAIT 11 Reset alarm 12 OFF 13 Interlock 14 Temperature 3 9V x 100 15 RF power amplifier current 3 9V x 75A 16 Forward Power 4 3V x F S 17 FAULT 18 Set...

Page 24: ...9 10 09 6 3 3 I2 C Connector Type DB9 Female 1 NC 2 SDA Serial Data 3 SCL Serial Clock 4 NC 5 GND GND 6 NC 7 NC 8 NC 9 NC 6 3 4 Com Bus Type DB15 male 1 GND 2 485 3 485 4 GND 5 ON OFF C 6 INP PWR 7 ST...

Page 25: ...4 23 25 26 28 31 33 16 NC 17 AC3 Internally connected with 35 18 NC 20 I TOT 19 AC4 Internally connected with 37 21 F PWR 22 INP PWR 23 GND Internally connected with 1 12 14 15 25 26 28 31 33 24 PS ST...

Page 26: ...ted 3 FUSE BLOWN Red LED that indicates the presence of one or more broken fuses 4 RF PWR ADJ Power regulation trimmer A G C control 5 ON Green LED indicating that the amplifier is switched on 6 FOLDB...

Page 27: ...erfacement with PS part 2 DB9 connector reserved for future uses 3 RF IN RF input connector N type 4 RF IN TEST Connector for the drawn not standardized of the modulator input signal 5 PLUG Plug for t...

Page 28: ...0 I TOT 19 AC4 internally connected with 37 21 F PWR 22 INP PWR 23 GND internally connected with 1 12 14 15 25 26 28 31 33 24 PS STATUS 25 GND internally connected with 1 12 14 15 23 26 28 31 33 26 GN...

Page 29: ...PJ2000M C PJ2500M C PJ3000M C 25 40 User Manual Rev 1 5 09 01 09 7 7 1 This page was intentionally left blank...

Page 30: ...PJ2000M C PJ2500M C PJ3000M C 26 40 User Manual Rev 1 5 09 10 09 This page was intentionally left blank...

Page 31: ...PJ2000M C PJ2500M C PJ3000M C 27 40 User Manual Rev 1 5 09 01 09 This page was intentionally left blank...

Page 32: ...this chapter Top View of PS secition with PFC 1 2 3 4 6 5 1 PS RF Interface Board SLINPSP2K01 PJ2000M C PJ2500M C SLINPSP2K03 PJ3000M C 2 Surge Protection Board SLSRGPRPJ2K1 3 PFC PFCPSL1000 PJ2000M C...

Page 33: ...01 09 Top View of PS section with Rectifier only PJ2000M C e PJ2500M C 1 2 3 4 5 6 1 PS RF Inteface board SLINPSP2K01 2 Surge Protection Board SLSRGPRPJ2K1 3 Rectifiers RCTPSL1000 4 Power Supply PSL10...

Page 34: ...Manual Rev 1 5 09 10 09 Top View of RF section mod PJ3000M C 1 2 3 4 5 1 Low pass Filter Board SLLPFPJ2KLST 2 Amplifier Modules SL046RF1001 3 Fuses Board SLFUSRFPJ4K1 4 Bias Boards SLMTPRTPJ4K1 CPU Bo...

Page 35: ...K1 4 Bias Boards SLMTPRTPJ2K1 CPU Board CPUPJ2KMC 5 LEDs Boards SLLEDRFPJ2K1 8 1 Power Supply Change To use the amplifier with different types of power supply you should connect the mains power supply...

Page 36: ...the external power supply plug must have the following characteristics PIN1 of the main connector is connected to Neutral wire PIN2 of the main connector is connected to Phase wire and internally conn...

Page 37: ...f the external power supply plug must have the following characteristics PIN1 of the main connector is connected to Neutral wire PIN2 of the main connector is connected to Phase R Wire PIN3 of the mai...

Page 38: ...e the machine Make the JP3 connection on the Rectifier card between PIN 1 and 2 to select 230 Volts or between PIN 2 and 3 for 115 Volts Figure 8 1 Connection for the selection of 115 or 208 230 Volts...

Page 39: ...supply modules are located in the middle part of the amplifier The power supply units are mounted on a cooling fin to cool the amplifier by forced ventilation The amplifier houses a transformer the i...

Page 40: ...transformer from which it receives the signals and to which it issues commands This interface card is designed to make the PS part communicate with the RF part and making available the dedicated signa...

Page 41: ...ve device used in the amplifier modules is a Mosfet 2x BLF278 in PJ3000M C model SD2942 in PJ2500M C model or BLF278 in PJ2000M C model 8 3 2 Wilkinson Splitter and Combiner Both the splitter and the...

Page 42: ...her one supplies the reflected power 8 3 6 Control Board The control board acts as an auxiliary card for the PROTF card in the PS section should the latter fail to trip due to a malfunction It impleme...

Page 43: ...can supply an output power of approximately 30W suitable to pilot PJ2000M C and PJ2500M C with a total gain of approximately 15dB The active device utilized in the amplifier modules is a Mosfet BLF17...

Page 44: ...PJ2000M C PJ2500M C PJ3000M C 40 40 User Manual Rev 1 5 09 10 09 This page was intentionally left blank...

Reviews: