14
/ 36
User Manual
Rev. 1.0 - 28/02/11
PJ1000C/1300C/2000LCD
ELETTRONICA
Figure 5.1:
connections with amplifier
WARNING: Electric shock hazard! Never handle the RF output connector
when the equipment is powered on and no load is connected. Injury or death
may result.
Ensure that the
POWER
switch on the front panel is set to “
OFF
”.
Connect the mains power cable to the MAINS terminal board on the rear panel.
Note :
The mains must be equipped with adequate ground connection properly
connected to the machine. This is a pre-requisite for ensuring operator safety and
correct operation.
WARNING: The power supply connector is a terminal board. Ensure the wire
is not live before performing the connection.
5.2 First power-on and setup
Follow this procedure upon first power-on and after making changes to the
configuration of the transmitter in which th amplifier is integrated.
Note :
Standard factory settings are RF output power off (
Pwr OFF
) and regulated
output power set to upper limit (unless otherwise specified by customer).
5.2.1 Pilot exciter setup
Set up the pilot exciter so that the output power it delivers to a matched load equals
the maximum input power indicated in the amplifier
final test table
, switch off the
exciter and connect it to the amplifier.