PJ1000C/1300C/2000LCD
ELETTRONICA
13
/ 36
User Manual
Rev. 1.0 - 28/02/11
Provide for the following (applicable to operating tests and putting into service):
√
Single phase mains power supply 115 or 230 VAC (±15%) for
PJ1000/
1300C-LCD
, or only 230 VAC (±15%) for
PJ2000LCD,
with adequate earth
connection.
√
For operating tests only: dummy load with 50 Ohm impedance and adequate
capacity (1000W for
PJ1000C-LCD,
1300W for
PJ1300C-LCD
or
2000W for
PJ2000LCD
as minimum).
√
Connection cable kit including:
• Mains power cable.
• Coaxial cable with BNC connectors for interlock signal connection between
exciter and amplifier.
• RF cable for output to load / antenna (50 Ohm coaxial cable with 7/16” EIA
flange).
5.1.2 Connections
Connect the output of a suitable FM exciter (for instance, PTX30LCD exciter
available from R.V.R. Elettronica) to the RF input using a 50 Ohm coaxial cable
with “N”-type connectors. To begin with, set exciter to minimum output power and
switch if off.
Connect the amplifier INTERLOCK OUT output to the matching INTERLOCK IN
input fitted on all R.V.R. Elettronica exciters as standard; if your exciter is a different
brand, identify an equivalent input.
Connect the RF output to an adequately rated dummy load or to the antenna.
The diagram of RF connection and control between the amplifier and its
exciter and connection with the load, is represented in Figure 5.2.