R.V.R. is never responsible for damage or loss), until 

the package reaches R.V.R. premises. For this reason, 

we suggest you to insure the goods for the whole value. 

Shipment  must  be  effected  C.I.F.  (PREPAID)  to  the 

address specified by R.V.R.’s service manager on the 

authorization

 

DO  NOT  RETURN  UNITS  WITHOUT  OUR 

AUTHORIZATION AS THEY WILL BE REFUSED

4  Be  sure  to  enclose  a  written  technical  report  where 

mention  all  the  problems  found  and  a  copy  of  your 

original  invoice  establishing  the  starting  date  of  the 

warranty.

Replacement  and  warranty  parts  may  be  ordered  from 

the  following  address.  Be  sure  to  include  the  equipment 

model and serial number as well as part description and 

part number.

 

R.V.R. Elettronica SpA 

Via del Fonditore, 2/2c 

40138 BOLOGNA ITALY 

Tel. +39 051 6010506

 

3.  First Aid

The  personnel  employed  in  the  installation,  use  and 

maintenance of the device, shall be familiar with theory and 

practice of first aid.

 

3.1  Treatment of electrical shocks

 

3.1.1  If the victim is not responsive

Follow the A-B-C’s of basic life support.

• 

Place  victim  flat  on  his  backon  a  hard 

surface.

• 

Open airway: lift up neck, push forehead back 
(

Figure 1

). 

Figure 1

• 

clear out mouth if necessary and observe for 

breathing

• 

if  not  breathing,  begin  artificial  breathing  

(

Figure 2

): tilt head, pinch nostrils, make airtight 

seal, four quick full breaths. Remember mouth 

to mouth resuscitation must be commenced as 

soon as possible.

Figure 2

• 

Check  carotid  pulse  (

Figure  3

);  if  pulse  is 

absent,  begin  artificial  circulation  (

Figure  4

depressing sternum (

Figure 5

).

           

      Figure 3

                    

Figure 4

Figure 5

• 

In case of only one rescuer, 15 compressions 

alternated to two breaths.

• 

If there are two rescuers, the rythm shall be of 

one brath each 5 compressions. 

• 

Do  not  interrupt  the  rythm  of  compressions 

when the second person is giving breath.

• 

Call for medical assistance as soon as  

possible.

 

3.1.2  If victim is responsive

• 

Keep them warm.

• 

Keep them as quiet as possible.

• 

Loosen  their  clothing (a  reclining  position  is 

recommended).

• 

Call for medical help as soon as possible.

 

3.2  Treatment of electrical Burns

 

3.2.1  Extensive burned and broken skin

• 

Cover  area  with  clean sheet or cloth.

• 

Do not break blisters, remove tissue, remove 

adhered particles of clothing, or apply any salve 

or ointment.

• 

Treat victim for shock as required.

• 

Arrange transportation to a hospital as quickly 

as possible.

• 

If  arms  or  legs  are  affected  keep  them 

elevated.

If  medical  help  will  not  be  available  within  an  hour  and 

the victim is conscious and not vomiting, give him a weak 

solution of salt and soda: 1 level teaspoonful of salt and 

1/2 level teaspoonful of baking soda to each quart of water 

(neither hot or cold).

Allow victim to sip slowly about 4 ounces (half a glass) over 

a period of 15 minutes. 

Discontinue fluid if vomiting occurs.

DO NOT give alcohol.

 

3.2.2  Less severe burns

• 

Apply cool (not ice cold) compresses using the 

cleansed available cloth article.

• 

Do not break blisters, remove tissue, remove 

adhered particles of clothing, or apply salve or 

ointment.

• 

Apply clean dry dressing if necessary.

• 

Treat victim for shock as required.

• 

Arrange transportation to a hospital as quickly 

as possible.

• 

If  arms  or  legs  are  affected  keep  them 

elevated.

Summary of Contents for GPSRXNV-01

Page 1: ...GPSRXNV 01 User Manual Volume 1 Manufactured by Italy ...

Page 2: ...rm or by any means electronic or mechanic including photocopying recording or by any informa tion storage and retrieval system without written permission of the copyright owner Name File 03_GPSRXNV 01_ING_1 0 indd Version 1 0 Date 16 11 2007 Revision History Date Version Reason Editor 16 11 2007 1 0 First Edition J H Berti Declaration of Conformity Hereby R V R Elettronica SpA declares that this F...

Page 3: ...Quick guide for installation and use 4 5 1 Preparation 4 6 External Description 8 6 1 Frontal Panel 8 6 2 Rear Panel 8 6 3 Connectors description 9 7 Technical Specifications 10 7 1 Mechanical Specifications 10 7 2 Electrical Specifications 10 7 3 Spare Parts 10 8 Module identification 12 8 1 Top View 12 9 Working Principles 13 9 1 Power supply card PSS1201 01 13 9 2 Interface card SL041IN1001 13 ...

Page 4: ...GPSRXNV 01 ii User Manual Rev 1 0 16 11 07 This page was intentionally left blank ...

Page 5: ... measures Specifications and informations contained in this manual are furnished for information only and are subject to change at any time without notice and should not be construed as a commitment by R V R Elettronica SpA The R V R Elettronica SpA assumes no responsability or liability for any errors or inaccuracies that may appear in this manual including the products and software described in ...

Page 6: ...sent begin artificial circulation Figure 4 depressing sternum Figure 5 Figure 3 Figure 4 Figure 5 In case of only one rescuer 15 compressions alternated to two breaths If there are two rescuers the rythm shall be of one brath each 5 compressions Do not interrupt the rythm of compressions when the second person is giving breath Call for medical assistance as soon as possible 3 1 2 If victim is resp...

Page 7: ...XNV 01 is compact design and user friendliness Another key feature is its modular concept design the different functions are performed by modules with most connections achieved through male and female connectors or through flat cables terminated by connectors This design facilitates maintenance and module replacement The GPSRXNV 01 contains a buffer battery to avoid possible lack of power supply a...

Page 8: ...ections with detailed descriptions of all hardware and firmware features and capabilities Please see the relevant sections for additional details The topics covered in this section are discussed at greater length in the next sections with detailed descriptions of all hardware and firmware features and capabilities Please see the relevant sections for additional details 5 1 Preparation 5 1 1 Prelim...

Page 9: ...his condition and set the switch to ON BATTERY position see figure 6 2 note 11 after powering the system 5 1 3 Connections Connect tge GPS ANTENNA input of GPSRXNV 01 see figure 6 2 note 11 to antenna receiver figure 5 1 Figure 5 1 Connect the 10MHz OUT 1 output of GPSRXNV 01 figure 6 1 note 4 to the proper IN 10MHZ input equipped with apparatus of R V R Elettronica like PTX LCD with SFN option fi...

Page 10: ...again when the phase locking of 10MHz e 1PPS signal happens the EBO OK will be again light on too In case that you made explicit request for purchase the software license of EPSILON BOARD OEM II card at time of order the reading parameters of GPSRXNV 01 and of satellites will be made through the serial connection between the RS232 and the DB9 placed in front panel and a compatible PC with Microsof...

Page 11: ... 14 User Manual Rev 1 0 16 11 07 GPSRXNV 01 Figura 5 3 ...

Page 12: ...S DB9 M connector for the alarm output status of the equipment through the contacts available 4 10MHz OUT 1 BNC connector for the signal output at 10MHz for the synchronism of the carrier 5 10MHz OUT 2 BNC connector for the auxiliary signal output at 10MHz for the synchronism of the carrier only in case of presence of proper option 6 10MHz OUT 3 BNC connector for the auxiliary signal output at 10M...

Page 13: ...41IN1001 is in pos 2 3 or 3 4 12V signalling in case of normal operation condition If JP6 SL041IN1001 is in pos 1 2 12V signalling in case of alarm If JP6 SL041IN1001 is in pos 4 5 12V always active 5 GND GND 6 EBO OK OUT dig Closed contact if PIN7 is in normal operating condition 7 EBO OK OUT dig Common contact 8 EBO OK OUT dig Closed contact if PIN7 is in alarm condition 9 EBO OK OUT an Tip JP5 ...

Page 14: ...ply 12VDC Accuracy to UTC with GPS locked 50 ns 1σ 10MHz output frequency accuracy 2 x 10 12 GPS system Integrated Antenna Input Connector N type Uscita 5V output for antenna power supply 1pps TTL output Connector BNC Typical level TTL 10MHz output Connector BNC Signal Form sinusoidal Typical level 5 dBm 50Ω Harmonic Distortion 25 dBc Connectors RS232 serial interface DB9 female connector to conne...

Page 15: ...7 3 Spare Parts Subsets for Maintenance Panel board SL041PC1001 Interface card and battery charger SL041IN1001 Power supply card PSS1201 01 Parts of parts Transformer TRFALT0001 GPS receiver EPSILON BOARD OEM II Buffery battery 12V 2Ah BATTPG12V2A2 ...

Page 16: ...onnectors to facilitate maintenance and replacement if needed 8 1 Top View The figure 8 1 shows a top view of the equipment and component locations Figure 8 1 1 Panel Board SL041PC1001 2 Buffer battery BATTPG12V2A2 3 Transformer TRFALT0001 4 Power supply card PSS1201 01 5 Interface card SL041IN1001 6 GPS receiver EPSILON BOARD OEM II ...

Page 17: ... supply of analog section and a voltage of 7 V for the power supply of digital logic section In case of absence of network and in case the switch on the rear panel of the battery is enabled the equipment automatically switches the power supply on the internal buffer battery thus guaranteeing the continuity of the service 9 2 Interface card SL041IN1001 This card performs the following tasksi Interf...

Page 18: ...Panel board SL041PC1001 This card is mounted on the frontal panel The panel board provides the visualization via LEDs related to status of equipment Also hosts the RS232 connector for direct serial communication normally used only for factory settings ...