To set subcarrier input levels, you may use the same procedure and option “x10”
available in the Fnc menu. With this option, modulation level is multiplied by a factor
of 10, which means that default menu bar meter reflects a 7.5 kHz deviation.
A special menu with separate indications of Left and Right channel levels and
relating indicators of nominal levels for maximum deviation (75 kHz) is provided.
• Preemphasis:
ON
1
2
3
4
50
m
s
ON
1
2
3
4
75
m
s
• L and R (XLR type) input impedance:
Switch 1: R XLR input impedance, ON = 600
W
, OFF = 10 k
W
Switch 2: L XLR input impedance, ON = 600
W
, OFF = 10 k
W
• MPX input operation mode/impedance:
Switch 1: Mode of operation ON = Mono, OFF = Stereo
Switch 2: MPX input impedance, ON = 50
W
, OFF = 10 k
W
5.3 Operation
1) Power on the transmitter and ensure that the
ON
light turns on. Equipment
name should appear briefly on the display, quickly followed by modulation
and forward power readings, provided that the transmitter is delivering output
power.
Menu 1
1b) To
modify power level setting
, hold down the
ENTER
button until opening
the
power setup menu
.
The edit screen will look like this:
Menu 2
O
N
1
2
O
N
1
2