10
/ 26
User Manual
Rev. 1.0 - 22/08/14
TEX1002LCD
√
For operating tests only: dummy load with 50 Ohm impedance and adequate
capacity (minimo 1000W per
TEX1002LCD
).
√
Connection cable kit including:
• Mains power cable.
• Coaxial cable with BNC connectors for interlock signal connection.
• RF cable for output to load / antenna (50 Ohm coaxial cable with standard 7/8”
connector).
• Audio cables between transmitter and audio sources.
5.1.2 Connections
Connect the RF output of the transmitter to the antenna cable or a dummy load
capable of dissipating transmitter output power. To begin with, set transmitter to
minimum output power and switch it off.
Connect the transmitter INTERLOCK IN input to the matching INTERLOCK OUT
output fitted on R.V.R. Elettronica equipment to act as hybrid couplers. If your
equipment is a different brand, identify an equivalent output.
Connect the RF output to an adequately rated dummy load or to the antenna.
WARNING: Electric shock hazard! Never handle the RF output connector
when the equipment is powered on and no load is connected. Injury or death
may result.
Ensure that the
POWER
switch on the front panel is set to “
OFF
”.
The transmitter has two switches: one is embedded in rear panel and interrupts
all mains power supply of the machine, while the second is on the front panel and
acts by inhibiting the switching power supply of the machine.
Connect the mains power cable to the MAINS connector on the rear panel.
Note : The mains must be equipped with adequate ground connection properly
connected to the machine. This is a pre-requisite for ensuring operator safety and
correct operation.
Connect the audio and RDS/SCA signals from user’s sources to the transmitter
input connectors.