BLUES30/50NV
ELETTRONICA
13
/ 28
User Manual
Rev. 1.0 - 29/11/16
The screen in edit mode will look like this:
The bottom line gives the instantaneous power (50W in this example), to increase
the level, turn to the right to turn to the left. Once you reach the desired level, press
the ENCODER to confirm and exit to the default menu. Note that the set value is
stored anyway, so if you leave the timeout without pressing any key, the power
will be the last level set.
The value at the side of
SET
provides a percentage indication of power setting;
please consider that the forward power readout provided on the display (
FWD:
xxxx W
) reflects actual output power reading,
which may be lower than regulated
power supply when Automatic Gain Control is running in power supply
limitation mode
(please read section 5.3 about RF power supply modulation for
more details).
NOTE:
Output power may be set using the
Pwr OFF
control. In this condition, the
output power readout (
Fwd
) on the display will read 0 (zero); the
SET
bar will reflect
any adjustments you make using the keys and provides a graphic indication of how
much power supply will be delivered the moment you return to
Pwr On
state.
5.2.5 Changing the
Power Good
alarm threshold
Change Forward Power Good alarm setting
PgD
from the
Fnc
menu as desired
(factory setting is 50%).
5.2.6 Setting equipment I
2
C address
Change the
IIC
address in the
MIX
(Miscellaneous) menu as desired (factory
setting is 01).
5.2.7 Adjustments and calibration
The only manual adjustments are the level adjustments and the audio mode
adjustment.
The rear panel holds the trimmers for all transmitter inputs. Trimmer identification
is printed on the rear panel. Input sensitivity can be set within the limits set out in
the tables below through the trimmers: