Maintenance
Routine and periodic maintenance
WARNING!
ELECTRIC SHOCK CAN KILL
Turn the input power OFF at the mains switch & fuse box and remove mains plug from socket before
working on this equipment.
Have a qualified electrician install & service this Plasma cutting equipment. Allow machine to sit for 5
minutes minimum after disconnection from mains power to allow the power capacitors to discharge before
working inside this equipment.
Do not touch electrically live parts
1. Periodically (3-6 months depending on use / environment), remove the side/top panels of
machine and clean out machine with a low pressure dry air line paying particular attention to PC
Boards, Fan blades and switchgear
2. Failure to maintain plant can void manufacturer’s warranty.
3. Inspect input and output cables & hoses for fraying and cuts, replace if damaged present
4. Keep cutting torch and earth cables in good condition
5. Clean air vents to ensure proper air flow and cooling
6. The fan motor has sealed bearings which requires no maintenance
Fault Diagnostics
1.
Power light not lit
Check machine on/off switch is in the on position, Check Input power to machine, Check plug wiring,
Check mains trip / fuses.
2.
No output - Fan runs - Power light is lit
Check torch connections are secure and torch switch operation, try replacing plasma cutting torch
13