PAGE 26
Power Cat 24 Volt 25 Amp
Sealed Battery Charger
EZlamp Code
Charger Phase
Flashing RED
Internal charger check – “Flooded Lead Settings”
Flashing RED & GREEN Internal charger check – “AGM Settings”
Steady RED
Indicates first and second phase of charge
Steady YELLOW
Indicates finish charge in progress
Steady GREEN
Indicates charge cycle is complete
TROUBLE SHOOTING
In the event that there is a problem with charger here is a simple trouble shooting guide.
If the unit does not power on
, assure that the plug for the charger is placed firmly in the wall
receptacle and that that the circuit breaker for that receptacle is not blown. Watch the “EZlamp”
indicator to see if any LEDs illuminate when it is plugged in. If no LEDs light try a different
power cord. If this does not fix the problem the charger needs to be replaced.
EZlamp Fault Codes
Problem
Solution
Continuous flashing RED
-
No connection to
battery
-
Battery connected in
reverse
-Check connections to battery
Flashing RED & YELLOW
-
Poor Connection
-
Check all connections
-
Verify battery was not
disconnected during
charge
-
Problem with battery
-
Check battery
-
Verify battery electrolyte
levels (lead acid only)