Page 2
06206-90(I)
FACTORY DEFAULT SETTINGS
INPUT:
- Sensor Input Setting: "05" Wind Monitor
- Input selector switch position: "Down" (Sensor)
OPTIONS:
- Averaging: "No"
- Right hand display window: "Max Wind Speed"
- Alarms: "No"
OUTPUT:
- Voltage Outputs: 0-5Vdc=0-100m/s / 0-5Vdc = 0-360°
- NMEA Serial Output Rate: "FST"
IMPORTANT NOTE!:
Before connecting any external devices, verify the above settings
are compatible with your application. If different, refer to the
wiring diagrams in the back of the manual for the correct settings.
CHANGING SETTINGS
Marine Wind Tracker parameters may be inspected or changed in
SETUP mode which is enabled by simultaneously pressing both
ENTER
and
SELECT
keys for about 4 seconds. When SETUP mode
is active, abbreviations identify each function and available options
as listed below. The
SELECT
key changes options or values. The
ENTER
key saves and moves to the next parameter.
Appearance of options depends on parameter settings.
Some options may be hidden.
DISPLAY
SETUP FUNCTION
Input / Sensor Type
InP 03
Wind Sentry
04
Wind Monitor-Jr
05
Wind Monitor
SEr
NMEA serial input
Ld2
Line Driver 4-20mA input (0-100 m/s)
Hd
Wind Monitor HD
Ldi
Line Driver 4-20mA input (0-50 m/s)
Wind Speed Units (annunciator blinks)
SPd unt
SELECT key changes units. ENTER to save
NMEA Serial Output Rate
Out FSt
16 times per second
SLO
Once per second
Display Averaging (annunciator blinks)
dSP no
Instantaneous data displayed
YES
Average data displayed
PEr 030
Set averaging period in seconds (0-999).
Display will update at this interval.
Right Display Window Selection
dSP SPd
Maximum wind speed
dir
Wind Direction degrees
Wind Direction Alarm (annunciator blinks)
ALr no
Direction alarm not armed
YES
Direction alarm armed
ALr dir
SELECT key sets direction alarm sector start.
ENTER key saves.
ALr SPn
SELECT key sets direction alarm sector span.
ENTER key saves.
FRONT PANEL
1. Wind speed display
2. Wind speed units indicator
3. Alarm status indicators
4. Data averaging indicator
5. Maximum wind speed or direction display
6. Wind direction and variability display
7. Brightness control (operate) or Enter key (setup)
8. Maximum Reset (operate) or Select (setup)
BACK PANEL
1. Power input coaxial jack (12-30 VDC)
2. Power input terminals (12-30 VDC)
3. Sensor or 4-20 mA inputs
4. Earth ground connection
5. RS-485 serial input/output
6. 0-5 VDC calibrated outputs
7. Alarm relay connections (Normally Open)
8. Input Selector Switch (Sensor or 4-20mA)