FACTORY DEFAULT SETTINGS

INPUT:

 

-  Sensor Input Setting:  "05" Wind Monitor

 

-  Input selector switch position:  "Down" (Sensor)

OPTIONS:

 

-  Averaging:  "No" 

 

-  Right hand display window:  "Max Wind Speed" 

 

-  Alarms:  "No"

OUTPUT:

 

-  Voltage Outputs:  0-5Vdc=0-100m/s / 0-5Vdc = 0-360° 

 

-  NMEA Serial Output Rate:  "FST"

IMPORTANT NOTE!:
Before connecting any external devices, verify the above settings 

are compatible with your application.  If different, refer to the 

wiring diagrams in the back of the manual for the correct settings.

CHANGING SETTINGS

Marine Wind Tracker parameters may be inspected or changed in 

SETUP mode which is enabled by simultaneously pressing both 

ENTER

 and 

SELECT

 keys for about 4 seconds.  When SETUP mode 

is active, abbreviations identify each function and available options 

as listed below. The 

SELECT

 key changes options or values. The 

ENTER

 key saves and moves to the next parameter.

Appearance of options depends on parameter settings. 

Some options may be hidden.

DISPLAY 

 

SETUP FUNCTION

 

 

 

Input / Sensor  Type

InP   03

 

Wind Sentry

 

04

 

Wind Monitor-Jr

 05

 

Wind Monitor

 

SEr

 

NMEA serial input

 

Ld2

 

Line Driver 4-20mA input (0-100 m/s)

 

Hd

 

Wind Monitor HD

 

Ldi

 

Line Driver 4-20mA input (0-50 m/s)

 

 

Wind Speed Units (annunciator blinks)

SPd unt

 

SELECT key changes units. ENTER to save

  

NMEA Serial Output Rate

Out FSt

 

16 times per second

 

SLO

 

Once per second

  

Display Averaging (annunciator blinks)

dSP no

 

Instantaneous data displayed

 

YES

 

Average data displayed

PEr 030

 

Set averaging period in seconds (0-999). 

 

 

Display will update at this interval.

  

Right Display Window Selection

dSP SPd

 

Maximum wind speed

 

dir

 

Wind Direction degrees

 

 

Wind Direction Alarm (annunciator blinks)

ALr no

 

Direction alarm not armed

 

YES

 

Direction alarm armed

ALr dir

 

SELECT key sets direction alarm sector start. 

 

 

ENTER key saves.

ALr SPn

 

SELECT key sets direction alarm sector span.

 

 

ENTER key saves.

FRONT PANEL

1.  Wind speed display

2.  Wind speed units indicator

3.  Alarm status indicators

4.  Data averaging indicator

5.  Maximum wind speed or direction display

6.  Wind direction and variability display

7.  Brightness control (operate) or Enter key (setup)

8.  Maximum Reset (operate) or Select (setup)

BACK PANEL

1.  Power input coaxial jack (12-30 VDC) 

2.  Power input terminals (12-30 VDC)

3.  Sensor or 4-20 mA inputs

4.  Earth ground connection

5.  RS-485 serial input/output

6.  0-5 VDC calibrated outputs

7.  Alarm relay connections (Normally Open)

8.  Input Selector Switch (Sensor or 4-20mA)

Summary of Contents for 06206

Page 1: ...OGICAL INSTRUMENTS INSTRUCTIONS R M YOUNG COMPANY 2801 AERO PARK DRIVE TRAVERSE CITY MICHIGAN 49686 USA TEL 231 946 3980 FAX 231 946 4772 WEB www youngusa com PN 06206 90 REV I111215 WIND TRACKER MODE...

Page 2: ...IONS INDOOR USE ONLY Unless placed in approved enclosure Operating temperature range 0 50 C 32 122 F 0 95 RH Use only recommended power sources 12 30 VDC 3 5 W Disconnect power when connecting or serv...

Page 3: ...m s Hd Wind Monitor HD Ldi Line Driver 4 20mA input 0 50 m s Wind Speed Units annunciator blinks SPd unt SELECT key changes units ENTER to save NMEA Serial Output Rate Out FSt 16 times per second SLO...

Page 4: ...d Tracker may be configured as a remote display by setting the Sensor Input for serial input InP SEr and connecting the RS 485 terminals to a source providing a WIMWV NMEA wind speed and direction str...

Page 5: ...at his own expense This ISM device complies with Canadian CES 001 Cet apparei ISM est conforme a Ia norme NMB 001 du Canada EN55011 CISPR 11 Group 1 Class B device Class B equipment is suitable for u...

Page 6: ...Page 5 06206 90 I WIRING DIAGRAMS WIND SENSOR 05103 04101 03002...

Page 7: ...Page 6 06206 90 I WIRING DIAGRAMS...

Page 8: ...R SETTINGS Output Mode RS 485 Output Only Output Format NMEA Baud Rate 4800 SENSOR SETTINGS Output Mode RS 485 Output Only Output Format NMEA Baud Rate 4800 06206 Wind Tracker with Inp SEr in setup 06...

Page 9: ...Page 8 06206 90 I Master Remote Display Wiring Example WIRING DIAGRAMS...

Reviews: