background image

www.rm-suttner.com

page 6, Ver. 10.2020

User manual easy

 ST-167 / ST-168 bypass-injectors

Product code.: 200 167 ... / 200 168 ...

Both the diffusor nozzle and the injector nozzle 

 

must be screwed in as far as it will go. 

 

By using Loxeal 56-03 the diffusor nozzle 

 

can be sealed up.

Injector nozzle (selection)

Inlet 1/2

"

 F

Loxeal 56-03

Counter nozzle (selection)

       

     Selection lever

Outlet 1/2

"

 F

Restriction 

 

(Selection)

Dosage of the chemical

Port: Cleaning agent 

 

(to foam)

Screw driver similar 

DIN 5265 shape A

7,0 mm

1,2 mm

Tool for changing a counter nozzle:

Selection of nozzles

       

   ST-168  

Port:

 

Compressed

 

air

Injector nozzle

Counter nozzle

040 003 641 (ø 1,1 mm) 040 003 514 (ø 1,4mm)
040 003 642 (ø 1,2 mm)

040 003 517 (ø 1,7 mm)

040 003 643 (ø 1,3 mm)
040 003 644 (ø 1,4 mm)
040 003 645 (ø 1,5 mm)

040 003 521 (ø 2,0 mm)

040 003 646 (ø 1,6 mm)
040 003 647 (ø 1,7 mm)
040 003 648 (ø 1,8 mm)

040 003 523 (ø 2,3 mm)

040 003 649 (ø 1,9 mm)
040 003 650 (ø 2,0 mm)
040 003 651 (ø 2,1 mm)

040 003 528 (ø 2,8 mm)

040 003 652 (ø 2,2 mm)
040 003 653 (ø 2,3 mm)
040 003 654 (ø 2,4 mm)
040 003 655 (ø 2,5 mm)
040 003 656 (ø 2,6 mm)

04 0003 532 (ø 3,2 mm)

040 003 657 (ø 2,7 mm)
040 003 658 (ø 2,8 mm)

Summary of Contents for easyfoam365+ ST-167

Page 1: ...or ST 75 or a surge regulator or multi regulator nozzle and be sprayed or foamed using the nozzle selected With the ST 168 no active i e separate air intake foam lance is necessary to generate the foa...

Page 2: ...nly Pressure Equipment Directive PED Group 2 liquids may be used as media In case of doubt contact the equipment manufacturer The unit may only be used with a suitable pressure generator The unit is n...

Page 3: ...via dosage nozzles or alternatively via the ST 161 dosage valve Depending on use the chemical water mixture can be sprayed or foamed via a suitable lance For foaming with the ST 167 a foam lance with...

Page 4: ...ure gun ST 1500 ST 2300 ST 2700 ST 167 Foam agent Cleaning agent Lance Nozzle High pressure gun ST 1500 ST 2300 ST 2700 ST 167 High pressure hose ID min 5 16 Length 20 m ID recom 3 8 Length 40 m Clean...

Page 5: ...350 bar Flow 4 l min High or low pressure device Pressure min 5 6 bar Pressure max 350 bar Flow 4 l min Foam hose PUReClean365 ID recom 1 2 Length max 20 m Foam hose PUReClean365 ID recom 1 2 Length...

Page 6: ...agent to foam Screw driver similar DIN 5265 shape A 7 0 mm 1 2 mm Tool for changing a counter nozzle Selection of nozzles ST 168 Port Compressed air Injector nozzle Counter nozzle 040 003 641 1 1 mm 0...

Page 7: ...100 0 45 l min dosage rate graph setting 2 read from diagram Concentration Flow Volume min 100 1 Dosage min 1 The flow volume can be read from a corresponding nozzle table 0 00 1 2 3 4 5 6 7 1 0 2 3...

Page 8: ...min dosage rate nozzle selection 1 2 read from diagram 0 00 0 5 0 6 0 7 1 0 1 1 1 2 1 3 1 5 0 20 0 40 0 60 0 80 1 00 1 20 1 40 1 60 1 80 10 l min 1 3 1 7 1 6 2 0 1 8 2 3 2 4 2 8 2 8 3 2 15 l min 20 l...