background image

www.rm-suttner.com

page 4, Ver. 10.2020

User manual easy

 ST-167 / ST-168 bypass-injectors

Product code.: 200 167 ... / 200 168 ...

Position:

Injector operation for 

washing operation

Assembly scheme: ST-167

Assembly scheme: ST-167

Lance

Nozzle

High pressure gun:

ST-1500, ST-2300, 

 

ST-2700

ST-167

Foam agent/ 

 

Cleaning agent

Lance

Nozzle

High pressure gun:

ST-1500, ST-2300, 

 

ST-2700

ST-167

High pressure hose.

ID min. 5/16“, Length 20 m.

 

ID recom. 3/8“, Length 40 m.

Cleaning agent

High pressure device.

Pressure min. 80 bar.

Flow min. 8 l/min.

High pressure device.

Pressure min. 80 bar.

Flow min. 8 l/min.

High pressure hose.

ID min. 5/16“, Length 20 m.

 

ID recom. 3/8“, Length 40 m.

Position:

Injector operation for 

cleaning agent

Summary of Contents for easyfoam365+ ST-167

Page 1: ...or ST 75 or a surge regulator or multi regulator nozzle and be sprayed or foamed using the nozzle selected With the ST 168 no active i e separate air intake foam lance is necessary to generate the foa...

Page 2: ...nly Pressure Equipment Directive PED Group 2 liquids may be used as media In case of doubt contact the equipment manufacturer The unit may only be used with a suitable pressure generator The unit is n...

Page 3: ...via dosage nozzles or alternatively via the ST 161 dosage valve Depending on use the chemical water mixture can be sprayed or foamed via a suitable lance For foaming with the ST 167 a foam lance with...

Page 4: ...ure gun ST 1500 ST 2300 ST 2700 ST 167 Foam agent Cleaning agent Lance Nozzle High pressure gun ST 1500 ST 2300 ST 2700 ST 167 High pressure hose ID min 5 16 Length 20 m ID recom 3 8 Length 40 m Clean...

Page 5: ...350 bar Flow 4 l min High or low pressure device Pressure min 5 6 bar Pressure max 350 bar Flow 4 l min Foam hose PUReClean365 ID recom 1 2 Length max 20 m Foam hose PUReClean365 ID recom 1 2 Length...

Page 6: ...agent to foam Screw driver similar DIN 5265 shape A 7 0 mm 1 2 mm Tool for changing a counter nozzle Selection of nozzles ST 168 Port Compressed air Injector nozzle Counter nozzle 040 003 641 1 1 mm 0...

Page 7: ...100 0 45 l min dosage rate graph setting 2 read from diagram Concentration Flow Volume min 100 1 Dosage min 1 The flow volume can be read from a corresponding nozzle table 0 00 1 2 3 4 5 6 7 1 0 2 3...

Page 8: ...min dosage rate nozzle selection 1 2 read from diagram 0 00 0 5 0 6 0 7 1 0 1 1 1 2 1 3 1 5 0 20 0 40 0 60 0 80 1 00 1 20 1 40 1 60 1 80 10 l min 1 3 1 7 1 6 2 0 1 8 2 3 2 4 2 8 2 8 3 2 15 l min 20 l...

Reviews: