Page 32
P&G Pilot 40A (D49525) Parameters
Functions
Notes
Setting
Set Acceleration
75%
Set Deceleration
55%
Set Turn Acceleration
35%
Set Turn Deceleration
60%
Set Forward Speed
100%
Set Reverse Speed
50%
Set Turn Speed
40%
Set Sleep Timer
0 Sec
Set Steer Correct
Veer Compensation.
0
Read Fault Log
Display Fault Code History.
Preset Control System
Restore Factory Defaults.
Help Mode
Diagnostics
Read Fault code
Engineering Menu
Set Soft Reverse
Prevent Reversing Digging In.
70%
Set Current Limit
Max & Min Current Limits.
40A Max-40A Min
Set Foldback Temp
Reduce Current At This Temp.
55
°C
Set Timed Foldback
Reduce Current After This Stall Time.
25%-60sec
Set Compensation
Match Motor Impedance.
130 m
-ohm
Set Battery Menu
Match Controller to Loom Resistance
64 m-ohm
Set Park Brake Trip
Chairs With No Brakes.
No
Set Front Drive
Front Wheel drive chairs.
No
Set Min Accn
43%
Set Min Decel’n
57%
Set Min Turn Accn
50%
Set Min Turn Decel’n
66%
Erase Fault Log
Preset Eng Values
Set To Factory Defaults.