R-Can Sterilight SC1 Installation, Operation And Maintenance Manual Download Page 4

1

 Parts:

Hard glass, coated Sterilume

®-

EX UV 

lamps for long, consistent life 

(9000 hours)

S212RL

FOR SC1, SC1/2

S287RL

FOR SC2.5, SC2.5/2

S330RL

FOR SC4, SC4/2

214 fused domed quartz sleeves 

with fire polished ends

qS-212D

FOR SC1, SC1/2

qS-287D

FOR SC2.5, SC2.5/2

qS-330D

FOR SC4, SC4/2

aluminum gland nut

RN-001

304 stainless steel reactors with 600 

grit polish (A249 pressure rated tube)

1/2” MNPT / 3/8” FNPT

combination ports for application 

flexibility

Axial flow reactor design for increased 

hydraulic efficiency

o-ring

OR-212

retaining clip

2 meters (6.5‘) 

power cord

integral ballast and lamp 

connector with green LED 

lamp/power indicator

ground wire

260120

NEW

mounting brackets - ROC-CC

Summary of Contents for Sterilight SC1

Page 1: ...and Maintenance sc1 sc2 5 sc4 sc1 2 sc2 5 2 sc4 2 425 Clair Road West P O Box 1719 Guelph ON N1L 1R1 Canada t 519 763 1032 f 519 763 5069 e water r can com i www r can com Manufactured in Canada by EP...

Page 2: ...ronmentally Friendly lamps throughout our entire product offering Low mercury Hg technology provides lamps with less than 10 mg of mercury including our amalgam lamps up to 70 less mercury than the co...

Page 3: ...ns 2 Water Chemistry 3 Installing Your UV Disinfection System 4 5 Operating and Maintenance Instructions 6 7 Fluence Dose Curves 8 Manufacture s Warranty 9 Specifications 10 11 Symbols Caution Protect...

Page 4: ...or sc2 5 sc2 5 2 qs 330d for sc4 sc4 2 aluminum gland nut rn 001 304 stainless steel reactors with 600 grit polish A249 pressure rated tube 1 2 MNPT 3 8 FNPT combination ports for application flexibil...

Page 5: ...to disconnect 7 Do not use this disinfection system for other than intended use potable water applications The use of attachments not recommended or sold by the manufacturer distributor may cause an...

Page 6: ...ess is less than 7 gpg the UV unit should operate efficiently provided the quartz sleeve is cleaned periodically If total hardness exceeds 7 gpg the water should be softened If your water chemistry co...

Page 7: ...s the disinfection system should be connected to a ground fault interrupt circuit The disinfection system is intended for indoor use only do not install disinfection system where it may be exposed to...

Page 8: ...TTACHED TO THE DISINFECTION SYSTEM AS THIS COULD DAMAGE THE O RING SEALS 4 Prior to connecting the power source check all connections to ensure that they are indeed secure slowly turn on water supply...

Page 9: ...t to angle the lamp as it is removed from the chamber If the lamp is removed on an angle pressure will be applied on the inside of the quartz sleeve causing the sleeve to fracture 3 To install a new l...

Page 10: ...he outside of the quartz sleeve with a cloth soaked in CLR or Limeaway Repeat the process as often as necessary to keep the quartz sleeve clean Be sure to remove all traces of cleaning fluid from the...

Page 11: ...8 Fluence Dose Curves SC1 SC1 2 SC2 5 SC2 5 2 SC4 SC4 2...

Page 12: ...1 mg L f UV Transmittance 75 call factory for recommendations on applications where UVT 75 Where total hardness is less than 7 gpg the UV unit should operate efficiently provided the quartz sleeve is...

Page 13: ...1 8 kg 4 lbs 2 0 kg 4 5 lbs 2 9 kg 6 5 lbs Electrical Voltage 100 130V 50 60Hz 100 130V 50 60Hz 100 130V 50 60Hz Power Consumption 12 w 16 W 19 w Lamp Watts 10 W 14 w 17 w Maximum Operating Pressure...

Page 14: ...ght 1 8 kg 4 lbs 2 0 kg 4 5 lbs 2 9 kg 6 5 lbs Electrical Voltage 200 250V 50 60Hz 200 250V 50 60Hz 200 250V 50 60Hz Power Consumption 12 w 16 W 19 w Lamp Watts 10 W 14 w 17 w Maximum Operating Pressu...

Reviews: