10
BA_BM_HS-300-MIDI_EN_44-21.docx
4.7
Hazardous Areas
Source
Area
Cause
Risk
Prevention
Foot pump
HS 300 MIDI | FH
only:
On the foot bar
for height adjust-
ment
Slipping off the
foot bar
Injuries to feet
and legs
Keep foot bar
and shoes dry
Wear work shoes
with non-slip soles
Mechanics
Lifting scissor /
Subframe
Crushing and
shearing points
Loss of limbs,
crushing of hands,
increased risk of
injury and even
death
Do not reach under the tab-
letop or into the scissors
during operation and do
not move your body into
this area
Before maintenance work,
always lock the safety catch
to secure the platform first
(see section
Hydraulic
system
On hydraulic
cylinders and all
oil-bearing parts,
seals and lines
Oil spraying
out with high
pressure in
case of damaged
cylinder or seals
Injuries and
poisoning of
the eyes
Wear safety goggles
or face shield
Repair damaged parts
and/or seals immediately
(only qualified personnel!)
Electrics
HS 300 MIDI | AH
only:
At the mains con-
nection and the
supply line of the
battery charger as
well as at the pole
terminals of the
12 V battery
Electrical voltage
(230 VAC) at the
battery charger as
well as high cur-
rents at the bat-
tery pole termi-
nals and further
cables
Electric shocks
with increased
risk of injury
up to death
Avoid moisture
Have defective parts / insu-
lation repaired immediately
(only qualified personnel!)
Do not touch energised
components
Switch off the main switch
during all maintenance and
repair work