Quorum Windmill 96015 Series Installation Instructions Manual Download Page 8

7. ELECTRICAL CONNECTIONS

REMEMBER 

-Turn off the power! 

NOTE

 - Control must be installed within 30 feet of fan.

Use the wire nuts supplied with your fan 
when making connections.  Secure the 
connectors with electrical tape and make 
sure there are no loose connections or wire 
strands.

1.

   Spread the wires apart so that the black 

wire from the fan is on one side of the 
mounting bracket and the white wire and 
green ground wire are on the other side.

2.

   (Fig. 17) Connect the BLACK building 

supply wire to the BLACK fan wires. 
Connect the WHITE building neutral wire 
to the WHITE fan neutral wire. Connect 
the COPPER building ground wire to the 
GREEN fan ground wire.

Carefully tuck the connected wires inside 
the junction box. Secure the transmitter 
with the two screws provided. Attach the 
face plate over the transmitter with the two 
screws provided.

Use 

ONLY

 remote controls approved 

by Quorum. Use of unapproved remote 
controls will cause unacceptable 
humming noise, and avoids the fan 
warranty.

Fig. 17

Fan 

Outlet box

Ceiling

WH

WH

BLK

B

LK

House 
supply 
wires

GRN

GROUND

Summary of Contents for Windmill 96015 Series

Page 1: ...ese instructions These instructions are to be used in the installation of the following QUORUM INTERNATIONAL fans The Windmill w optional light feature P O Box 961008 Fort Worth TX 76161 817 626 5483...

Page 2: ...stions regarding the warranty or the procedures for obtaining service please call us at 817 626 5483 Monday thru Friday 8 00 a m 5 00 p m CST technical skill competence or experience of the user 8 Lig...

Page 3: ...NG CONTACTYOUR DEALER FOR REPLACEMENT OR CALL QUORUM DIRECTLYAND WE WILL MAIL REPLACEMENTS TO YOU IMMEDIATELY 1 To avoid possible electric shock turn off the electricity at the main fuse box or circui...

Page 4: ...nds 22 7 kg WARNING Support Directly from the Building Structure 3 Secure the outlet box or make sure the existing box is secured directly to the building structure Use appropriate fasteners and build...

Page 5: ...ASSEMBLY SHOULD BE WORKED AT THE FLOOR 3 Remove the set pin and safety lock clip from the yoke on top of the motor assembly Slide the downrod through the canopy and canopy cover Slide the yoke cover o...

Page 6: ...e the blade circle Align the holes on the blade deco bars and secure with the blade deco bar screws Screw No 2 as show on Fig 10 Caution Do not tighten screws at this point All screws will be tightene...

Page 7: ...ow is the time to tighten all the blade and blade arm screws Be sure all screws are fully tightened Be sure not to forget screws No 1 and No 2 Fig 15 6 Lift the fan motor with the blades and place int...

Page 8: ...he other side 2 Fig 17 Connect the BLACK building supply wire to the BLACK fan wires Connect the WHITE building neutral wire to the WHITE fan neutral wire Connect the COPPER building ground wire to th...

Page 9: ...o set screws lift canopy cover and attach by turning clockwise Note Adjust the canopy screws as necessary until the canopy and canopy cover are snug Fig 18 8 COMPLETING THE INSTALLATION 9 INSTALLING T...

Page 10: ...rol will come on when the button is pressed The fan has completed the pairing process with the remote control and is ready for use NOTE A single fan can be controlled with as many as 3 remote controls...

Page 11: ...Periodically check tightness of all screws securing the blades to the blade arm attachment points A clicking or a rattling noise is a sure indication of loosening screws Since screws will invariably w...

Page 12: ...against the canopy possibly vibrating while the fan is on 3 Use of a standard light rheostat or an unapproved fan remote control to control the fan speed will always cause an annoying hum Many fan mot...