QM1004A-2-18 Combined RF Upconverter/Downconverter
User Manual
2. EtherNET Subsystem Command Reference
2.1 EtherNET:GATEway <ipString>
This command sets the Gateway of the Combined RF Upconverter/Downconverter.
Syntax
:
ENET
:
GATE
Space
"xxx.xxx.xxx.xxx"
?
Example
:ENET:GATE "192.168.2.1"
This command sets the Gateway to 192.168.2.1
Default Condition
On startup, the Gateway defaults to the previously programmed value. The default Gateway is 192.168.2.1.
Query
:ENET:GATE?
This query returns the system’s current Gateway.
Error Message
If the ipString is not in the recognized format, error
-102, "Syntax error"
occurs.