QM1004-0.5-18 Combined RF Upconverter/Downconverter
User Manual
2. FREQuency Subsystem Command Reference
2.1 FREQuency:BYPASS [1
|
0]
This command allows the user to bypass the converter and pass the RF input to the IF output.
Syntax
1
:
FREQ
:
BYPASS
Space
0
?
Example
:FREQ:BYPASS 1
This command bypasses the frequency converter
.
Default Condition
On power up, or when a
*RST
command is issued, the QM1004-0.5-18 returns to the boot state’s setting.
The Combined RF Upconverter/Downconverter default setting is 0.
Query
:FREQ:BYPASS?
This query returns the state of the frequency converter bypass setting.
Error Message
If the parameter is not in the recognized format, error
-102, "Syntax error"
occurs.
If the parameter is not 0 or 1, error
-222, "Data out of range"
occurs.
Quonset Microwave
Revision 1.2.1
34