Network nodes with gateway WTX16.GSM/IP/MOD-1 

10.09.2009 

Basic diagram 

The WT…16… consists of the following blocks: 

tr

ans

ceiver for

 Q

 A

M

net

wor

k

M-Bus 

Master 

5 un

it 

loads

RS232

 

*) WTX16.GSM only 

**) WTX16.IP only 

The transmitter and the receiver are used to 
collect data from the consumption meters and 
to forward theses data to other nodes in the 
network the data memory stores the consump-
tion data. It is protected against temporary 
mains power failures by the backup battery. 
The network nodes WTX16.GSM and 
WTX16.IP are equipped with a gateway to 
store data of up to 2000 meters and to provide 
a possibility for remote readout via GSM or 
Ethernet. The gateway has an additional M-
Bus master that can drive up to 5 additional 
external M-Bus unit loads (e.g. up to 5 addi-
tional M-Bus meters). Usually, however, the 
M-Bus master is used to connect nodes of 
different networks to be able to read more 
meters using only one gateway. 
For extension of M-Bus, is it possible to con-
nect a repeater to the gateway. 
The gateway can be programmed using an 
additional RS232 interface. 

 
 
 
 
 
 

 

***) user programmable 

The network node WTX16.MOD-1 is equipped 
with a gateway for remote readout via GSM or 
GPRS. 
It has no M-Bus master, though. Therefore it 
can read data from one network only (max. 
500 meters).  

 

WTX16.GSM 
WTX16.IP 

WTX16.MOD-1 

Summary of Contents for WTX16.GSM

Page 1: ...been designed for use in buildings to create a radio network for receiving and storing the data transmitted by the consumption meters installed in the building Communication between several net work n...

Page 2: ...ster Max number of meters WTX16 GSM Network node with gateway remote readout via GSM yes 5 additional unit loads 2000 WTX16 IP Network node with gateway remote readout via Ethernet yes 5 additional un...

Page 3: ...ay to store data of up to 2000 meters and to provide a possibility for remote readout via GSM or Ethernet The gateway has an additional M Bus master that can drive up to 5 additional external M Bus un...

Page 4: ...electrical connections are made The electronics section is identical for all types of network nodes It contains control ele ments of the network RESET MODE DISPLAY 1 2 3 4 6 7 11 10 8 9 5 1 Connector...

Page 5: ...y DC 3 6 V 2 Indication of mains supply red LED 3 permanently installed cable no flexible cable 4 SIM card holder WTX16 GSM only 5 RS232 interface for servicing 6 Connector for M bus service connectio...

Page 6: ...red LED 3 permanently installed cable no flexible cable 4 SIM card holder WTX16 MOD only 5 RS232 interface for servicing 6 Connector for M bus service connection 7 Anschluss f r M Bus 8 mains connect...

Page 7: ...It can also be started manually with the ACT26 service tool Installa tionsmode2 In installation mode the radio network will be built up automati cally Metering devices that transmit installation tele...

Page 8: ...The registration of the device takes place and search mode starts Delete from version 2 2 for example If an already registered IrDA capable metering device is connected in IrDA master mode it can be r...

Page 9: ...ss II Then the live L and neutral N conductors must be connected to terminal IN of the power pack Mains voltage must be in the range from AC 100 to 240 V 50 60 Hz There is no protective earth PE conne...

Page 10: ...for voice and data service SIM cards only sold for voice service or M2M service cannot be used For that purpose remove the upper section of the WTX16 GSM from the base Press the SIM card slightly in...

Page 11: ...tained Staff dealing with the product must be familiar with all potential hazards and maintenan ce measures in accordance with the instructions given in this document It must be possible to disconnect...

Page 12: ...cy of transmission 1 Permanent ambient temperature Transport and storage Operation 20 60 C 30 C recommended 0 55 C Weight 0 3 kg Dimensions 184 31 8 9 7 200 6 0 R 1 5 0 R 100 150 250 2 5 0 R 55 250 2...

Reviews: