Chapter 3: Installation
3-3
Rack Install
Locate the
Tenor BX
unit within the same area as your PBX, Ethernet hub, switch, router, and/or
PSTN patch panel. The chassis is intended to be installed in a 19” rack.
Mounting brackets are attached to the chassis; the rack is not included with your system. Included
with the chassis are the screws listed below. The sizes should allow installation in most racks. If
your rack does not use the same size screws listed in the table, please consult the instructions you
received with the rack.
Required Materials
•
19” rack (optional, not included with system)
•
#8 - 32 x 3/8 screws (qty: 2) (included with the system)
•
screws as required by your rack manufacturer
Install the chassis in a rack as follows:
1. Choose a position for the chassis within the rack.
WARNING:
If the
Tenor BX
unit is the only equipment installed in the rack, ensure it is level with
the rack to avoid the rack from becoming unbalanced. Mount as low as possible to
avoid a high center of gravity.
2. Align the unit’s mounting brackets flush with the rack’s mounting holes (see
Figure 3-1
) and fol-
low the vendor specific instructions for rack installation. The screws provided require a Phillips
#2 screwdriver.
3. Ensure the chassis is secured firmly to the rack.