Figure 10.  SIP Configuration Tab.

 

SIP CONFIGURATION TAB 

Summary of Contents for ITA-200

Page 1: ...__________________________ _____________________________________________________________________________________ Copyright 2004 2006 Quintum Technologies Inc All Rights Reserved 1 of 58 Intelligent Telephone Adapter Model ITA 200 Technical Reference Manual Revision 1 0 October 26 2006 ...

Page 2: ...A 200 Cables 11 Power Up Sequence 12 Chapter 4 Configuring the ITA 200 13 1 Unit Information tab 14 2 WAN LAN Configuration tab 15 3 SIP Configuration tab 19 4 Services tab 23 5 Misc Servers tab 27 6 Maintenance tab 29 Chapter 5 Firmware Upgrade ITA200 31 1 Download firmware 31 2 Auto Firmware update 32 3 Special download 33 Chapter 6 Voice prompts 35 1 List of command prompts 35 2 Data input for ...

Page 3: ...t port of a Broadband Modem ADSL or Cable the LAN Port of the ITA 200 adapter connects to the Ethernet port of the PC providing the PC with connectivity to the Internet At the same time it provides the user with two 2 additional telephone lines The typical configuration diagram is shown below Figure 1 Typical Configuration The ITA 200 uses your broadband connection to deliver high quality voice co...

Page 4: ...r for easy installation HTTP Server for Web Management supports 2 compressed voice channels simultaneously G 729A or G 723 1 for bandwidth management a sophisticated Quality of Service QoS for crystal clear communication supports enhanced features such us call waiting call forwarding 3 way calling caller ID and many more that make the ITA 200 the only solution for your VoIP network General Specifi...

Page 5: ... Remote Procedure Call FTP File Transfer Protocol RLOGIN Remote Login RSH Remote Shell Telnet The Internet Standard Protocol for Remote Login SNTP Simple Network Transfer Protocol NAT Network Address Translation QoS Quality of Service Data prioritization VPN Virtual Private Network PPTP Point to Point Tunneling Protocol IPSec Internet Protocol Secured VoIP Interface Specifications Two FXS Analog T...

Page 6: ...and selective Distinctive Ringing Voice Mail Message Waiting Warning Tone Lamping 3 Way Conference Calling Off Hook Warning Tone Speed Dialing Hotline Dialing Security HTTP Web Configuration Password Protected Administrator and End User Passwords Multiple End Users Password Telnet Password Protected SIP Digest Encrypted Authentication via MD5 Provisioning Integrated Web Server for Configuration Au...

Page 7: ...______________________________________ _____________________________________________________________________________________ Copyright 2004 2006 Quintum Technologies Inc All Rights Reserved 7 of 58 Regulatory Compliance FCC Part 15 Class B VCCI CE Mark Front View Back View ...

Page 8: ...0 ___________________________________________________________________ _____________________________________________________________________________________ Copyright 2004 2006 Quintum Technologies Inc All Rights Reserved 8 of 58 Standing View ...

Page 9: ... Figure 2 ITA 200 Front Panel LED description Power Green ITA 200 is powered on Phone 1 Phone 2 Green The telephone is off hook Off The telephone is on hook and in service Blinking Slow The telephone is not in service or not registered with a SIP server Blinking Fast The unit is downloading firmware from the TFTP or HTTP server WAN Speed Off 10 Mbps connection Yellow 100 Mbps connection WAN Link A...

Page 10: ...odem hub switch or router LAN RJ 45 This LAN Local Area Network port connects to the PC Phone 1 and Phone 2 RJ 11 telephone sockets that connect to the analog telephone devices or facsimile machines Reset Button The reset button can be use in two ways reset the ITA 200 to factory defaults by pressing the Reset button for more than five 5 seconds or restart the ITA 200 by pressing the Reset button ...

Page 11: ...net port to the LAN port of the ITA 200 using the other RJ 45 Ethernet cable c Connect Phone1 port of the ITA 200 to a telephone or fax machine using a standard RJ 11 telephone cord Repeat the same step for the Phone2 port Remarks The telephone must be configured for tone dialing rather than pulse dialing in order for the ITA 200 to operate properly d Connect the 12 volts AC Power Adapter to the p...

Page 12: ..._____ Copyright 2004 2006 Quintum Technologies Inc All Rights Reserved 12 of 58 Power Up Sequence a Turn on your computer b Power up the ITA 200 c Power up the Cable DSL Modem and verify that the modem has successfully connected to the ISP s Internet Service Provider network by checking its LED s Figure 5 indicates the power up sequence for the ITA 200 Figure 5 Sequence to power up ITA 200 ...

Page 13: ...ed 13 of 58 Chapter 4 Configuring the ITA 200 Your ITA 200 should be configured as shown in Figure 5 and all the LED s should be ON except Phone 1 and Phone 2 To access the ITA 200 s configuration web page type 192 168 10 1 in the address field of your Windows Internet Explorer Press the Enter key and the following screen as shown in Figure 6 will display Use the default username admin and passwor...

Page 14: ...ersion Boot Version Displays the ITA 200 s current boot file version Backup Version The backup firmware version of the ITA 200 MAC Address The hardware address that uniquely identifies ITA 200 as a node in the network Serial Number This is the serial number assigned by the manufacturer WAN IP Address This IP address uniquely identifies ITA 200 as a node in the IP network for example the Internet W...

Page 15: ...o all the web pages for configuration he has to enter in the password the following combination the last 2 digits of the MAC address plus the 7th and 8th digits of the MAC address followed by quta200 For example MAC address 000f26001f88 the password will be 8800quta200 password is in lower case The web page with all the configuration option is shown in Figure 8 Figure 8 Complete web pages for conf...

Page 16: ...on the Internet that translates Internet names such as WWW addresses to numeric IP addresses The DNS addresses are normally provided by your ISP Domain Name The Internet name for a network or computer system that identifies one or more IP addresses Domain names are used in URLs to identify particular Web pages LAN INTERFACE CONFIGURATION Enable Local DHCP Server To enable the ITA 200 s DHCP server...

Page 17: ...by the ITA 200 to communicate with the Control Panel software The default value is 60434 Use Control Panel Only for LAN Purpose Enable this option if you want to use the 3 Way Video Conferencing Control Panel software behind the LAN without Internet connection The default option is Disabled Control Panel Information Guest Passwords Line 1 or Line 2 The password is for authorization to connect the ...

Page 18: ...___________________________________________________________ _____________________________________________________________________________________ Copyright 2004 2006 Quintum Technologies Inc All Rights Reserved 18 of 58 Figue 9 WAN LAN Configuration Tab ...

Page 19: ..._________________________________________________ _____________________________________________________________________________________ Copyright 2004 2006 Quintum Technologies Inc All Rights Reserved 19 of 58 Figure 10 SIP Configuration Tab SIP CONFIGURATION TAB ...

Page 20: ...on Server Interval s Specifies the periodic time interval that ITA 200 re registers itself to the SIP Registration Server The default value is 660 seconds Local SIP Port The local port used by ITA 200 to communicate with SIP Proxy Server The default value is 5060 NAT Timer Specifies the periodic time interval that ITA 200 sends a UDP packet to keep the port open The default value is 15 seconds SIP...

Page 21: ...h as G 711 and G 726 It provides a fairly simple approach to moving data traffic over IP and enables the handling of a variety of legacy V series modem traffic This method tends to be bandwidth intensive but does not require a gateway to demodulate the modem data in order to transport it The basic concept is consistent with the methods that various vendors have used on a private i e non standard b...

Page 22: ...________________________________________________________________ _____________________________________________________________________________________ Copyright 2004 2006 Quintum Technologies Inc All Rights Reserved 22 of 58 Figure 11 Services Tab ...

Page 23: ... Waiting on your line Call Waiting is selected by default in the manufacturer configuration Enable 61 Disable 60 Block Anonymous Caller Anonymous Call Rejection ACR allows you to reject all subsequent calls that do not have a caller ID number If your ACR is turned on and you receive a blocked call your phone will not ring and the call will be dropped ACR is not selected by default in the manufactu...

Page 24: ...all Return If your telephone stops ringing before you are able to answer it or if you wish to call the last person you were speaking with Call Return allows you to automatically dial the last caller s number providing his her Caller ID number has not been blocked Call Return is selected by default in the manufacturer configuration Enable 69 Disable 79 Call Forwarding Option All If Call Forwarding ...

Page 25: ...ected by default in the manufacturer configuration Refer to Appendix A for more detail Dial Key Dial key option is used for shortcut or speed dialing Enter the shortcut key the number to be replaced with and check the Enable checkbox Off hook Auto Dialing If this option is enabled the unit will dial the off hook dialing number automatically whenever the phone is off hook Reverse Polarity Select po...

Page 26: ...erved 26 of 58 Enable RTP Proxy Enable this option to include special code that will force the softswitch to do RTP proxy Be aware this only work with specific servers do not enable this option unless you service provider allows it Enable Encryption SIP RTP If this option is enabled the unit will apply encryption to the SIP messages and RTP packets that are sent to the server This encryption will ...

Page 27: ...nload the configuration file automatically after every interval set in this field The values are in minutes and the minimum value interval is 1 min To disable this option set the Timer value to zero 0 Default values is 5 min Unit s WAN IP Address The WAN IP address of ITA 200 SIP Signaling WAN Port The WAN port used for the voice call Control Panel WAN Port The WAN port used to connect the control...

Page 28: ... SIP log will be sent to this SIP Log Server This feature is especially useful for ITSP Internet Telephony Service Provider Log Server Port The port of the SIP Log Server Inter Digit Time Out When dialing a number if you don t press at the end of the dialing the ITA 200 will wait for the time specified in this field before proceed to make the call The default is 4 seconds DMT Server IP Defines the...

Page 29: ...ATES Download Firmware Select this option to download firmware from the HTTP or TFTP server specified in the Misc Server tab Download Configuration File Select this option to download configuration file from the HTTP or TFTP server specified in the Misc Server tab Reset Hardware To restart ITA 200 Special Downloads System Access Code Required This is used to download special firmware The System Ac...

Page 30: ...when there is a new firmware available in the server This discovery occurs during the reset of the unit ADMINISTRATION CHANGE PASSWORD Admin Option to change the password for the admin user Default admin password admin User Option to change the password for the non admin user Telnet Option to change the telnet password Default Telnet password password Create user This option can only used by the A...

Page 31: ...file For details on how to create the update file refer to Appendix B 1 Connect the pc to the Lan port of the ITA200 and login to the unit with all privilege To login with full access Refer to page 15 2 Select Misc servers tab 3 On the Firmware Config Server add the IP or domain name of the HTTP TFTP server and select the type of server Note if the server is HTTP the ITA200 will try to access the ...

Page 32: ...he ITA200 and login to the unit with all privilege To login with full access Refer to page 15 2 Select Misc servers tab 3 On the Firmware Config Server add the IP or domain name of the HTTP TFTP server and select the type of server Note if the server is HTTP the ITA200 will try to access the subdirectory you have specified on the Firmware Config field to look for the firmware or configuration file...

Page 33: ...an port of the ITA200 and login to the unit with all privilege To login with full access Refer to page 15 2 Select Misc servers tab Figure 14 3 On the Firmware Config Server add the IP or domain name of the HTTP TFTP server and select the type of server Note if the server is HTTP the ITA200 will try to access the subdirectory http domain wata200 to look for the firmware or configuration file 4 Pre...

Page 34: ...um Technologies Inc All Rights Reserved 34 of 58 Figure 17 Special Download Figure 18 Special Download 9 Select Download Firmware and input the exact name of the file on the Firmware filename Figure 19 10 To finish click on Submit Request 11 When finished and to check the firmware upgrade select the Unit Information page the Firmware version is displayed and will display the new version number Fig...

Page 35: ...2 To Enter Password for PPPoE connection 13 To set Wan Connection Type 1 dhcp 2 PPPoE 3 Static 14 Enter IP address for static connection 15 Enter Subnet Mask for static connection 16 Enter Gateway for static connection 17 DHCP server 1 to enable 0 to disable 18 Remote Access 1 to enable 0 to disable 50 Firmware Backup Boot Firmware Upgrade 51 Firmware Upgrade Only 52 Config Upgrade 53 Wavefile Upg...

Page 36: ...quired letter and press to capture it Press 0 to toggle between uppercase and lowercase modes whenever necessary Press 10 to backspace delete previous letter End the entry by pressing 5 At the end of the entry you will hear the following Voice To confirm press 1 To re enter press 2 To go back to the main menu press pound 6 Confirm the entry by pressing 1 Wait for a few seconds the username will be...

Page 37: ...u press pound 6 Confirm the entry by pressing 1 Wait for a few seconds the password will be saved to the box and you will hear the following Voice Stored successfully Please enter the commands 7 You can continue by entering the next command or hang up the phone Entering IP To Enter IP address Subnet and Gateway you just have to dial the number corresponding to the octet follow by the asterisk to c...

Page 38: ...P server running and must have the config file For details on how to create the config file refer to Appendix C 1 Connect the pc to the LAN port of the ITA200 and login to the unit with all privilege To login with full access Refer to page 15 2 Select Misc servers tab 3 On the Firmware Config Server add the IP or domain name of the HTTP TFTP server and select the type of server Note if the server ...

Page 39: ...ith all privilege To login with full access Refer to page 15 2 Select Misc servers tab 3 On the Firmware Config Server add the IP or domain name of the HTTP TFTP server and select the type of server Note if the server is HTTP the ITA200 will try to access the subdirectory you have specified on the Firmware Config field to look for the firmware or configuration file Example www company com config_d...

Page 40: ...server 1 Connect the pc to the Lan port of the ITA300 and login to the unit with all privilege To login with full access Refer to page 15 2 Select Misc servers tab 3 On the Firmware Config Server add the IP or domain name of the HTTP TFTP server and select the type of server Note if the server is HTTP the ITA300 will try to access the subdirectory you have specified on the Firmware Config field to...

Page 41: ...For example 224455 The in a dial plan is used to separate each component of that dial plan 011x This part of the dial plan allows for international calls 011 The international dialing prefix for North America x Any single digit from 0 9 inclusive the period in the above sequence that the preceding digit can be repeated one or more times In the above example the preceding digit is an x representing...

Page 42: ...o sequence of numbers 011 2 9 x This part of dial plan allows for international calls 011 The international dialing prefix for North America 2 9 Any single number from 2 to 9 inclusive 2 3 4 5 6 7 8 or 9 In this case the first digit in the country code the user is trying to call x Any single digit from 0 9 inclusive The period in the above sequence that the preceding digit can be repeated one or m...

Page 43: ...numbers that matches the remainder of the dial string 2 4 xxxxxxx with 1727 2 4 Anything enclosed with in brackets represents 1 number In the above case it s a number range allowing either a 2 3 or 4 to fit the dial plan xxxxxxx x represents any single number between 0 and 9 In the case of the above xxxxxxx any six individual numerical digits would match the dial plan e g 123456 654321 555555 etc ...

Page 44: ...nit and it will compare the version with the one that the unit has and if the version is greater the unit will download and install it On the server folder along with the configuration and firmware file there should be an update file with the file name quta200update with no extension The content of the file should have the following format TYPE VERSION FILENAME If it is not on the above format the...

Page 45: ...s txt in txt format Example If the ITA 200 has the Mac Address number 000F26001234 save the template with the following name prf000f26001234 txt The following is an example of a config file ext 0 enableProxyServer 0 proxyIp 0 0 0 0 proxyPort 0 regIp 0 0 0 0 regInterval 660 regPort 0 logIp 0 0 0 0 logPort 0 natIp 0 0 0 0 natPort 0 enableNatTimer 0 natTimer 15 enableBckProxy 1 bckProxyIp 0 0 0 0 bck...

Page 46: ...admin userPwd admin enableP2PDialing 0 enableBack2BackDialing 0 autoNetworkConnect 0 P2P1Ip 0 0 0 0 P2P2Ip 0 0 0 0 P2P3Ip 0 0 0 0 P2P4Ip 0 0 0 0 P2P5Ip 0 0 0 0 P2P1Ext1 1000 P2P2Ext1 2000 P2P3Ext1 3000 P2P4Ext1 4000 P2P5Ext1 5000 P2P1Ext2 1000 P2P2Ext2 2000 P2P3Ext2 3000 P2P4Ext2 4000 P2P5Ext2 5000 enableP2P1 0 enableP2P2 0 enableP2P3 0 enableP2P4 0 enableP2P5 0 primaryNTPTimeZone GMT 5 00 US East...

Page 47: ...min enableReversePolarity 0 localSIPPort 5060 bckLocalSIPPort 0 macAddress 000f26000000 localAreaCode enableLocalAreaCode 0 rtpProxy 0 starHashCode 0 enablePhone1 1 phoneNumber1 5001 displayName1 interedge authenticationID1 interedge enableAuthID1 0 phonePwd1 admin voiceSilenceSuppression1 1 voiceFrameSize1 4 voiceCodec1 1 G 723 1 voiceCodec1 2 G 729A voiceCodec1 3 G 711 PCMU voiceCodec1 4 G 729AB...

Page 48: ...eSuppression2 1 voiceFrameSize2 4 voiceCodec2 1 G 723 1 voiceCodec2 2 G 723 1 voiceCodec2 3 G 723 1 voiceCodec2 4 G 723 1 voiceMediaPort2 27005 t38Port2 15004 enableCallWaiting2 1 enableCallForwarding2 0 callForwardingAll2 0 callForwardingOnBusy2 0 callForwardingOnNoAnswer2 0 callForwardingNumber2 1000 enableCallTransfer2 1 enableCallConferencing2 1 enableDoNotDisturb2 0 enableCallReturn2 1 enable...

Page 49: ...For Changes the SIP Server Information These settings are used by ITA 200 to communicate with the SIP Proxy Server proxyIp This field contains the URL string or IP address of the SIP Proxy Server enableProxyServer Enter 1 for enable or 0 for disable proxyPort The default port of SIP Proxy Server is 5060 this file can be change for other value regIp This field contains the URL string or IP address ...

Page 50: ...or 0 for disable phoneNumber1 The telephone numbers of your ITA 200 displayName1 The Caller ID s of the telephone numbers authenticationID1 The authentication ID used when registering the telephone numbers to the SIP Registration Server enableAuthID1 Will enable Authentication Enter 1 for enable or 0 for disable phonePwd1 The password is for authorization with the SIP proxy MD5 SIP authentication ...

Page 51: ..._________________ Copyright 2004 2006 Quintum Technologies Inc All Rights Reserved 51 of 58 Figure 23 DOS Command Prompt 4 Use binconv to crate configuration file for this execute the command as follows binconv prfmacaddress txt watamacaddress Example if the Mac Address is 000f26001234 then command should be binconv prf000f26001234 txt wata000f26001234 Figure 24 Execute binconv ...

Page 52: ... phoneNumber1 5010 Phone Number for line 1 displayName1 interedge Display name for line 1 authenticationID1 interedge Authentication ID for line 1 enableAuthID1 0 Enable authentication ID for line 1 Enable 1 Disable 0 phonePwd1 inter Password for line 1 voiceSilenceSuppression1 1 Silence Suppression for line 1 enable 1 disable 0 voiceFrameSize1 4 Number of frame size to be used on line 1 Default 4...

Page 53: ...the Secondary Signaling Port open bckNatTimer 15 Nat interval in seconds Default 15 seconds interDigitTimer 6 Seconds to wait between the digits before making a call sec dialKey1 2222 Dial Key 1 dialKey2 3333 Dial Key 2 dialKey3 4444 Dial Key 3 dialKey4 5555 Dial Key 4 dialKey5 6666 Dial Key 5 dialKey1Replace 0 Replace Key 1 dialKey2Replace 0 Replace Key 2 dialKey3Replace 0 Replace Key 3 dialKey4R...

Page 54: ...2 2000 Second Point to Point Dialing Remote Line 1 Extenstion P2P1Ext3 3000 Third Point to Point Dialing Remote Line 1 Extenstion P2P1Ext4 4000 Fourth Point to Point Dialing Remote Line 1Extenstion P2P1Ext5 5000 Fifth Point to Point Dialing Remote Line 1Extenstion P2P2Ext1 1000 First Point to Point Dialing Remote Line 2 Extenstion P2P2Ext2 2000 Second Point to Point Dialing Remote Line 2 Extenstio...

Page 55: ...ableCallTransfer1 0 Call Transfer on Line 1 Enable 1 Disable 0 enableCallTransfer2 0 Call Transfer on Line 2 Enable 1 Disable 0 enableCallConferencing1 1 3 way calling on Line 1 Enable 1 Disable 0 enableCallConferencing2 1 3 way calling on Line 2 Enable 1 Disable 0 EnableDoNotDisturb1 0 Do Not Disturb on Line 1 Enable 1 Disable 0 EnableDoNotDisturb2 0 Do Not Disturb on Line 2 Enable 1 Disable 0 en...

Page 56: ...it Services star codes are set in the following order enablecallwaiting disablecallwaiting enabledonotdisturb disabledonotdisturb enablecallconference disablecallconference enablecalltransfer disablecalltransfer enablecallredial disablecallredial enablecallreturn disablecallreturn enableblockanonymous disableblockanonymous entercallforwardingnumber disablecallforwarding callforwardingAll callforwa...

Page 57: ...ncyNumber2 PSTN emergency Number 2 pstnEmergencyNumber3 PSTN emergency Number 3 pstnEmergencyNumber4 PSTN emergency Number 4 pstnEmergencyNumber5 PSTN emergency Number 5 enablePstnEmergencyNumber1 0 Enable PSTN Emergency Number1 Enable 1 Disable 0 enablePstnEmergencyNumber2 0 Enable PSTN Emergency Number2 Enable 1 Disable 0 enablePstnEmergencyNumber3 0 Enable PSTN Emergency Number3 Enable 1 Disabl...

Page 58: ...tains network configuration examples and techniques using Quintum Technologies Inc And in some cases other company s products this examples are a recommendation only and does not constitute any legal arrangement between Quintum Technologies Inc And the reader either written or implied The network examples in this manual should be regarded as a guide to assist the user in forming his or hers own de...