7
Technical data
7.1
Reference conditions and limitations
Reference conditions
Effective working pressure of the
compressor
bar(e)
13
Effective working pressure of the
compressor
psig
190
Compressor running hours per day
h
12
Oil type
Organoclay
QuinSyn Plus, QuinSyn Endura, QuinSyn
Edge, QuinSyn Prime, QuinSyn Flex or any
other synthetic oil.
Compressor type
All types of oil-injected compressors
The reference conditions for the condensate treatment device distinguish 3 climate types:
• Cold climate: ambient temperature of 15 °C (59 °F) and relative humidity of 60 %
• Mild climate: ambient temperature of 25 °C (77 ºF) and relative humidity of 60%
• Hot climate: ambient temperature of 35 °C (95 ºF) and relative humidity of 70%
Limitations for operation
Minimum ambient temperature
˚C
1
Minimum ambient temperature
˚F
33.8
Maximum ambient temperature
˚C
46
Maximum ambient temperature
˚F
115
Minimum condensate inlet temperature
˚C
1
Minimum condensate inlet temperature
˚F
33.8
Maximum condensate inlet temperature
˚C
60
Maximum condensate inlet temperature
˚F
140
Maximum oil content at outlet of the condensate treatment
device
mg/l
10
7.2
Technical data
Compressor FAD
For poly-glycol based condensates, the capacity of each unit should be
halved.
Installation with compressors, air receivers, filters and dryers:
Instruction book
2920 7197 51