QOCS 106 – QOCS 1325
QOCS 360
1
Condensate inlet
2
Mufflers
3
Oleophilic filters (first stage)
4
Service indicator (oleophilic filter)
5
Service indicator (unit clogged)
6
Drain
7
Organoclay filter (second stage)
8
Condensate outlet
9
Test valve
10
Diffuser
11
Test capsule storage compartment
The condensate, containing fine oil droplets, enters the unit via the Inlet (1) into the mufflers (2)
and is depressurized. The condensate flows to the first tower and seeps through an oleophilic
filter (3), which absorbs most of the oil.
The water from the first stage, still containing a small quantity of oil, gradually flows to a second
stage, where an organoclay filter is fitted (7). The second stage filter starts to absorb the
remaining oil in the condensate.
The clean condensate is drained to the condensate outlet (8).
The oleophilic filter floats on the water. The more oil the filter absorbs, the deeper it will sink, and
service indicator (4) will move downwards with the filter. The filter must be replaced when the
service indicator is down.
Instruction book
2920 7197 51
9