Section I - General Information
Safety Precautions
Read this manual and follow all instructions
prior to installing or operating the
compressor.
Listed below are some, but not all, safety
precautions that must be observed with
compressors and compressed air systems.
WARNING!
Failure to follow any of these precautions
may result in severe personal injury,
death, property damage and/or
compressor damage.
Air from this compressor will cause
♦
severe injury or death if used for
breathing or food processing. Air
used for these processes must
meet OSHA 29 CFR 1910.134 or
FDA21XDE178.3570 regulations.
Disconnect and lockout all power
♦
supplies to the compressor plus any
remote controllers prior to servicing the
unit.
Never assume it is safe to work on the
♦
compressor because it is not operating.
Many installations have automatic start/
stop controls and the compressor may
start at any time.
This compressor is designed for use in
♦
the compression of normal atmospheric
air only. No other gases, vapors or
fumes should be exposed to the
compressor intake, nor processed
through the compressor.
Relieve all pressure internal to the
♦
compressor prior to servicing. Do not
depend on check valves to hold system
pressure.
A properly sized pressure relief valve
♦
must be installed in the discharge
piping ahead (upstream) of any shutoff
valve (block valve), heat exchanger,
orifice or any potential blockage
point. Failure to install a pressure
relief valve could result in the rupturing
or explosion of some compressor
component.
Do not change the pressure setting of
♦
the pressure relief valve, restrict the
function of the pressure relief valve, or
replace the pressure relief valve with
a plug. Over pressurization of system
or compressor components can occur,
resulting in death, severe personal
injury or property damage.
Never use plastic pipe, rubber hose,
♦
or soldered joints in any part of the
compressed air system. Failure to
ensure system compatibility with
compressor piping is dangerous.
Never use a flammable or toxic solvent
♦
for cleaning the air filter or any parts.
Do not remove any guards or cabinet
♦
panels or attempt to service any
compressor part while the compressor
is operating.
Do not operate the compressor at
♦
pressures in excess of its rating.
Observe control panel displays daily
♦
to ensure compressor is operating
properly.
Follow all maintenance procedures and
♦
check all safety devices on schedule.
Never disconnect or tamper with the
♦
high air temperature (HAT) sensors.
Compressed air is dangerous, do not
♦
play with it.
2
Summary of Contents for QGV-20
Page 2: ......
Page 70: ...Appendix A Dimensional Drawings QSI 90 120 140 micro 66...
Page 71: ...Appendix A Dimensional Drawings QSI 90 120 140 micro dry 67...
Page 72: ...Appendix A Dimensional Drawings QSI 90 120 140 micro tank mounted 68...
Page 73: ...Appendix A Dimensional Drawings QSI 90 120 140 micro dry tank mounted 69...
Page 74: ...Appendix A Dimensional Drawings QSI 90 120 140 guage 70...
Page 75: ...Appendix A Dimensional Drawings QSI 90 120 140 guage dry 71...
Page 76: ...Appendix A Dimensional Drawings QSI 90 120 140 guage tank mounted 72...
Page 77: ...Appendix A Dimensional Drawings QSI 90 120 140 guage dry tank mounted 73...
Page 78: ...Appendix A Dimensional Drawings QGV 20 25 30 460V 74...
Page 79: ...Appendix A Dimensional Drawings QGV 20 25 30 460V dry 75...
Page 80: ...Appendix A Dimensional Drawings QGV 20 25 30 460V tank mounted 76...
Page 81: ...Appendix A Dimensional Drawings QGV 20 25 30 460V dry tank mounted 77...
Page 91: ......