Section VI - Compressor Fluids
Cleaning and Flushing With QuinSyn Flush
Normal Machines
Flushing
clean
machines presently using:
A. Mineral Oils -
Drain compressor thoroughly while
hot including all the low areas. Shut
down and lockout the machine.
Detach lines and drain. Inspect
machine; if clean, change fi lters and
separator elements and proceed as
follows:
Fill with QuinSyn Flush and run
machine until it reaches normal
operating temperature. Drain and
refi ll with a fresh charge of the
QuinSyn fl uid selected for your
machine. Send a fl uid sample to
Quincy Compressor
®
Fluid Analysis at
200 hours.
B. Polyalklene glycols (PAG) or Silicone -
Drain compressor thoroughly as in
(A). Fill machine with QuinSyn Flush
and run for 500 hours. Send a fl uid
sample to Quincy Compressor
®
Fluid Analysis. Flush may need to
be repeated several times. Analysis
will determine if further fl ushes are
needed.
Fill with the QuinSyn fl uid selected
for your machine. Send a fl uid
sample to Quincy Compressor
®
Fluid
Analysis at 200 hours.
Varnished Machines
Always clean
slightly varnished
machines
using mineral oils or PAO fl uids with
QuinSyn Flush using the following
procedure:
Drain thoroughly as in (A) and fi ll with
QuinSyn Flush. Run the machine for 300
hours and take a fl uid sample. Send fl uid
sample to Quincy Compressor
®
Fluid
Analysis to determine if further fl ushes are
needed. Continue compressor operation
until results of fl uid analysis are reported.
Drain or continue operation as advised by
fl uid analysis.
Always clean
medium to heavily varnished
machines using mineral oils or PAO fl uids
with QuinSyn Flush using the following
procedure:
Drain thoroughly as in (A) and fi ll with
QuinSyn Flush. Run the machine for 300
hours and take a fl uid sample. Send fl uid
sample to Quincy Compressor
®
Fluid
Analysis to determine if further fl ushes are
needed. Run the fl ush for an additional
300 hours. Drain thoroughly as in (A) and
inspect the compressor. If clean, fl ush
with another half charge of QuinSyn Flush
and run for 30 minutes. Drain completely.
Change fi lters and separator elements
and fi ll with a fresh charge of the QuinSyn
fl uid selected for your machine. Send
fl uid sample to Quincy Compressor
®
Fluid
Analysis at 200 hours.
Extremely varnished
machines should not
be put back into service until mechanically
or chemically cleaned. After proper
cleaning, fi ll with a fresh charge of the
QuinSyn fl uid selected for your machine.
Send fl uid sample to Quincy Compressor
®
Fluid Analysis at 200 hours.
52
Summary of Contents for QGV-20
Page 2: ......
Page 70: ...Appendix A Dimensional Drawings QSI 90 120 140 micro 66...
Page 71: ...Appendix A Dimensional Drawings QSI 90 120 140 micro dry 67...
Page 72: ...Appendix A Dimensional Drawings QSI 90 120 140 micro tank mounted 68...
Page 73: ...Appendix A Dimensional Drawings QSI 90 120 140 micro dry tank mounted 69...
Page 74: ...Appendix A Dimensional Drawings QSI 90 120 140 guage 70...
Page 75: ...Appendix A Dimensional Drawings QSI 90 120 140 guage dry 71...
Page 76: ...Appendix A Dimensional Drawings QSI 90 120 140 guage tank mounted 72...
Page 77: ...Appendix A Dimensional Drawings QSI 90 120 140 guage dry tank mounted 73...
Page 78: ...Appendix A Dimensional Drawings QGV 20 25 30 460V 74...
Page 79: ...Appendix A Dimensional Drawings QGV 20 25 30 460V dry 75...
Page 80: ...Appendix A Dimensional Drawings QGV 20 25 30 460V tank mounted 76...
Page 81: ...Appendix A Dimensional Drawings QGV 20 25 30 460V dry tank mounted 77...
Page 91: ......