background image

Page 4 

 

 

 

Section 1: Safety Warning: 

Section 1.1: Safety warning 

This ‘EQ LTE product wide’ safety warning 
should be read and understood. Additional 
safety information is contained in this manual. 
Both the EQ LTE product wide and additional 
safety information contained in the manual 
must be read and understood. 

 

Warning: 

Risk of danger 

Warning: 

Risk of electric shock 

Warning: 

Risk of high pressure 

Warning: 

Risk of burn 

Warning: 

Risk of fire 

Warning: 

Consult manual 

 

Do not install or operate the EQ LTE™ 
product(s) (hereinafter can be referred to as 
the device) until you and all personnel 
concerned have read and established a 
working understanding of the device inclusive 
of duties to be performed while installing, 
operating and maintaining the device. 

 

This manual contains IMPORTANT SAFETY 
DATA and should be printed and kept with the 
device at all times. 

 

Improper use of the device may compromise 
the safety and protection of the device and its 
environment. 

 

Never use the device in explosive 
environments. 

 

Use only CATIII 600V or better insulated, test 
leads and voltage probes as supplied with the 
device. 

 

Before use, verify current clamp, test leads 
and voltage probes for damage or wear 
indicators, dispose of and replace when 
damaged or worn. 

 

No serviceable parts inside, dispose according 
to local regulations. 

 

Wall adaptor is part of a SELV circuit, use only 
supplied net adapter. 

 

Don’t mix lead and voltage probe colors and 
disconnect unused leads to prevent short 
circuits. 

 

Do not expose this device to heat, fire or direct 
sunlight. 

 

When installing, commissioning, operating or 
carrying out service or maintenance on the 
device, personnel must use relevant safe 
working practice and observe all relevant local 
health and safety requirements and 
regulations. 

 

Lethal voltages may be present at or around 
the device. Electricity has the potential to 
cause severe personal injury or death. Use 
extreme caution when carrying out checks 
where lethal voltages may exist. 

 

Never remove or tamper with safety devices, 
guards or insulation materials fitted to the 
device or the compressed air installation. 

 

Compressed air has the potential to cause 
severe personal injury or death. Use extreme 
caution when carrying out compressed air 
related checks. 

 

Hot and cold surfaces may be present at or 
around the device. Use caution as necessary 

 

A requirement of fault-free operation and 
fulfilment of any right to claim under guarantee 
is that documentation is observed. 

 

This document is subject to change without 
notice, if in doubt, do not proceed! 

 

It is not possible to anticipate every 
circumstance that might represent a potential 
hazard. If the operator employs an operating 
procedure, an item of equipment or a method 
of working which is not specifically 
recommended the user must ensure the 
product will not be damaged or made unsafe 
and that there is no risk to persons or property. 
Failure to observe safety precautions or 
implement safe working practices may be 
considered dangerous practice or misuse of 
the device. 

 

Section 1.2: Installation 

 

Installation work must only be carried out by a 
competent person under qualified supervision 
equipped with the correct tools and 
appropriate protection against hazards. 

 

When necessary, locate the emergency power 
off before installing the device; never work 
alone if potentially hazardous conditions exist. 

 

Disconnect the power before connecting the 
device, never assume power is off but always 

Summary of Contents for EQ LTE 2014900479

Page 1: ...Equipment Technical Manual Base Station...

Page 2: ...wer Supply 100 240vAC input DC output power supply c w plug assortment Note No case is supplied with this kit items are supplied loose EQ LTE Logger Pressure 0 16BAR complete case kit 2014900357 20149...

Page 3: ...t Logger assembly EQ LTE Sensor moisture dewpoint EQ LTE Sensor moisture dewpoint mounting chamber EQ LTE Power Supply 100 240vAC input DC output power supply c w plug assortment EQ LTE Logger 4 20mA...

Page 4: ...st use 4 2 4 General operation 4 2 5 Power supply 4 2 6 Logger battery compartment 4 2 7 Keypad 4 2 7 1 Bluetooth key and LED 4 2 7 2 Diagnostic key and LED 4 2 8 Data logger installation 4 2 9 EQ LTE...

Page 5: ...hat an organization or website is referred to in this work as a citation and or a potential source of further information does not mean that the author or the publisher endorses the information the or...

Page 6: ...he licensed materials including the specific design and structure of individual programs constitute trade secrets and or copyrighted material of Quincy Compressor Customer agrees not to disclose provi...

Page 7: ...the device personnel must use relevant safe working practice and observe all relevant local health and safety requirements and regulations Lethal voltages may be present at or around the device Elect...

Page 8: ...the ratings supply voltage frequency pressure temperature altitude humidity and environmental rating for which it is designed Do not operate the device without battery door enclosure open or covers r...

Page 9: ...ated The very latest Bluetooth technology then enables this information to be effortlessly transferred from multiple data loggers to a single intelligent EQ LTE base station In turn the base station t...

Page 10: ...g device ID serial number and original equipment manufacturer bar code data is located on the back elevation of the base station 4 1 2 Preparing for first use Each EQ LTE base station is supplied with...

Page 11: ...onment and EQ LTE data loggers Once EQ LTE data loggers return from the audit location simply synchronize with the EQ LTE base station once more and transfer your logged data from the EQ LTE base stat...

Page 12: ...Wizard configuration files from base station to logger s using Bluetooth Base to logger s Distributing logger configuration files to loggers Logger s to base Used to transfer data files from logger s...

Page 13: ...t locks either side of carry handle Transportation feet for stability when stacked Formed cushion insert Tamper resistant label providing device ID serial number and original equipment manufacturer ba...

Page 14: ...data loggers also feature an external power supply input This is used to power the data logger sensor Note The use of an external power supply unit does not eliminate the use of or need for the data...

Page 15: ...Slow flash Not configured Troubleshooting Create audit configuration transfer from cloud to base station and then from base station to logger Fast flash Configured not sensing data Troubleshooting Ch...

Page 16: ...ing temp 0 C 55 C 32 F 131 F Power batteries Four AA lithium primary cells Li SOCI2 3 6V 2700mAh Real time clock Precision real time clock temp compensated crystal Maximum deviation 0 4s day Sample ca...

Page 17: ...wet environments Do not use the device if it operates incorrectly Protection can be compromised Examine the test leads for damaged insulation or exposed metal Check test lead continuity Replace damage...

Page 18: ...deviation 0 4s day Sample capacity More than 1 4 million samples 16 days continuous logging Sample frequency 1 second fixed resolution 4 2 10 2 Sensor installation Warning risk high pressure Isolate...

Page 19: ...and should be chosen according to practical constraints Observe and maintain safe working practices at all times Identification EQ LTE Logger temperature 2014900365 EQ LTE EQ LTE Temperature data log...

Page 20: ...point data logger Precision data logging Definition Function Logger A D resolution 16 bits Bluetooth slave 2 1 EDR enhanced data rate Bluetooth range 10 meters 33 feet The effective range varies due t...

Page 21: ...ets at the sensor element Condensation or water on the sensor element may cause a fault and may corrupt sensor data The size of the inlet and outlet pipe diameter sections must not be less than the sp...

Page 22: ...present in area L of the diagram below Be aware that the air flow sensor is directional L Length of pipe section At inlet L1 15 x inner pipediameter At outlet L2 5 x inner pipe diameter D Inner diamet...

Page 23: ...39 69 Oxygen O2 176 4 578 74 Nitrous oxide N2O 181 4 595 14 Natural gas NG 109 4 358 92 DIN 1343 0 C 1013 25mbar Maintenance The sensor head should be checked regularly for dirt and cleaned if necessa...

Page 24: ...slave 2 1 EDR enhanced data rate Bluetooth range 10 meters 33 feet The effective range varies due to propagation conditions material coverage production sample variations antenna configurations and b...

Reviews: