Page 17
4.2.12 EQ LTE™ moisture data logger
4.2.12.1 Technical data
4.2.12.2 Sensor installation
Warning risk high pressure. Isolate
gas connection from the compressed
air system (e.g. gate or ball valve)
before attempting to locate the
moisture sensor
. Read and
understand all safety instructions
for both EQ LTE™ data logger
and the compressed air
installation and consider any risks
where the data logger will be
located before proceeding.
If in doubt stop immediately!
The sensor is supplied complete with
measuring chamber. The measuring chamber
features a quick release coupling.
Connect sensor and measuring chamber
assembly to the compressed using the quick
release coupling.
In case of compressed air containing oil and
dirt particles a pre-filter should be installed in
front of the measuring chamber.
Compressed air flows continuously in the
capillary pipe of the measuring chamber.
Note:
The location of the moisture sensor may
vary according to the parameter monitored.
Placing a moisture sensor in front and behind
a dryer allows evaluating a dryer’s
performance level.
1
2
3
Identification:
EQ LTE™ Logger, moisture
Product family:
EQ LTE™
EQ LTE™ Moisture (dew point)
data logger
Precision data logging
Definition:
Function:
Logger:
A / D resolution:
16 bits
Bluetooth slave:
2.1 + EDR (enhanced data rate)
Bluetooth range:
10 meters (33 feet)
The effective range varies due to propagation conditions,
material coverage, production sample variations, antenna
configurations and battery conditions
Operating temp:
0°C ~ +55°C (+32°F ~ +131°F)
Power supply:
110 – 240v AC
Real time clock:
Precision real time clock
(temperature compensated crystal)
Maximum
deviation:
0.4s / day
Sample
frequency:
1 second (fixed resolution)
Sample capacity:
More than 1.4 million samples (16
days continuous logging or more)
Software:
Pre-programmed application
software
Sensor & measuring chamber:
Ambient
conditions:
0°C ~ +50°C
(+32°F ~ +122°F)
Accuracy:
2°C dew point
Sensor conn:
Material:
G½
Stainless steel
Chamber conn:
Quick release coupling
Prevost ERP07.6153
Mating conn:
Prevost ESG07.1153
or compatible alternative
Measure range:
-80°C ~ +20°C dew point
(-112°F ~ +68°F)
0 ~ 100% relative humidity
-30°C ~ +70°C
(-24°F ~ +158°F)
Pressure range:
-1 ~ +16 bar (-14.35 ~ +232 psi)
Response time:
> 30 sec (descending), >10 sec
(ascending)
Sensor casing:
Zinc, alloy, PC & ABS
Conformity
DIN EN 61326
Combined:
External
protection:
Polypropylene case, molded
cushion insert
Dimensions:
Logger (W x H x D)
98 x 203.2 x 34.8mm
3.8 x 8.0 x 1.3 inch
Sensor (Diameter x H)
30mm x 109mm
1.1 x 4.3 inch
Polypropylene case (W x H x D)
437 x 379 x 100mm