Instruction book
7
4
9829 3199 7
4
9.5
Reference conditions
Reference
Unit
Value
Absolute inlet pressure
bar(a)
1
Relative air humidity
%
0
Air inlet temperature
˚C
20
Note: if the compressor is to operate at an altitude of more than 1000 m above sea level, it is
possible that the maximum pressure and/or the maximum speed must be decreased. Consult
Quincy.
9.6 Limitations
Maximum air inlet temperature
40 ˚C
104 ˚F
Minimum ambient temperature
0 ˚C
32 ˚F
Maximum relative humidity of ambient air
100 % at temperatures
below 35 ˚C (95 ˚F), 70
% at 40 ˚C (104 ˚F)
Maximum altitude operation (see note)
1000 m
3281 ft
Minimum working pressure
4 bar(e)
58 psig
Summary of Contents for QOFT 20
Page 1: ...QOFT 20 QOFT 25 QOFT 30 QOFT 40 QOFT 50 QOFT 60 Instruction book...
Page 2: ......
Page 47: ...Instruction book 9829 3199 74 45 Dimension drawing QOFT 40 up to QOFT 60 compressor...
Page 82: ......
Page 83: ......
Page 84: ...www quincycompressor com Performance You Demand Reliability You Trust No 9829 3199 74 2020 04...