![Quincy Compressor QGD 40 Instruction Book Download Page 97](http://html1.mh-extra.com/html/quincy-compressor/qgd-40/qgd-40_instruction-book_3767994097.webp)
Condition
Fault
Remedy
Insufficient cooling air or cooling air
temperature too high
Check for cooling air restriction or
improve ventilation of the
compressor room. Avoid
recirculation of cooling air. If
installed, check capacity of
compressor room fan
Oil cooler clogged
Clean cooler
Bypass valve malfunctioning
Have valve tested
Air cooler clogged
Clean cooler
Compressor element out of order
Consult your supplier
Cooling air fan does not deliver
enough air.
Unit shuts down due to
overtemperature, fan overload, too
high oil consumption or less FAD.
Fan rotates in the wrong direction
due to wrong electrical
connection.
Faults and remedies, dryer
For all references hereafter, consult section
.
Condition
Fault
Remedy
Pressure dew point too high
Air inlet temperature too high
Check and correct; if necessary, clean the
aftercooler of the compressor
Ambient temperature too high Check and correct; if necessary, draw
cooling air via a duct from a cooler place or
relocate the compressor
Shortage of refrigerant
Have circuit checked for leaks and
recharged
Refrigerant compressor does
not run
See below
Evaporator pressure too high
See below
Condenser pressure too high
See below
Condenser pressure too high
or too low
Fan control switch out of
order
Replace
Fan blades or fan motor out of
order
Have checked fan/fan motor, if necessary
replace.
Ambient temperature too high Check and correct; if necessary, draw
cooling air via a duct from a cooler place or
relocate the compressor
Condenser externally clogged Clean condenser
Compressor stops or does not
start
Electric power supply to
compressor is interrupted
Check and correct as necessary
Thermal protection of
refrigerant compressor motor
has tripped
Motor will restart when motor windings have
cooled down
Instruction book
2920 7190 02
95
Summary of Contents for QGD 40
Page 1: ...Quincy Oil injected rotary screw compressors QGD 40 QGD 50 QGD 60 Instruction book...
Page 2: ......
Page 14: ...Front view compressors with integrated dryer Instruction book 12 2920 7190 02...
Page 15: ...Front view open compressors without dryer Instruction book 2920 7190 02 13...
Page 16: ...Rear view compressors without dryer Instruction book 14 2920 7190 02...
Page 17: ...Front view open compressors with integrated dryer Instruction book 2920 7190 02 15...
Page 112: ......
Page 113: ......