• To= Air receiver temperature K
10. To prevent feedback of exhaust air to the cooling inlet, sufficient space should be foreseen
above the unit to evacuate the exhaust air.
4.3
Electrical connections
Important remark
To preserve the protection degree of the electric cubicle and to protect its components from
dust from the environment, it is mandatory to use a proper cable gland when connecting the
supply cable to the compressor.
Electrical connections
Reference
Designation
(1)
Customer’s installation
(2)
All voltages (50 and 60 Hz)
Instructions
1. Provide an isolating switch.
2. Check that the motor cables and wires inside the electric cabinet are clamped tight to their
terminals.
3. Check the fuses and the setting of the overload relay. See section
4. Connect earth conductor bolt (PE).
5. Connect the power supply cables to their terminals L1, L2, L3.
Instruction book
2920 7190 02
69