QUILL FALCON MOBILE 4 MAN AIR
BREATHING UNIT
- SHUTTING DOWN
1.
To switch off emergency air. Open emergency air bottle cupboard door
3.
Open bleed screw by twisting anti clockwise. Close after empty
4.
Close main air inlet valve on mobile unit, wait for the siren noise to start
6.
Close main air inlet valve on compressor and switch compressor off
2.
Close air bottle valve by twisting clockwise, close emergency air bottle cupboard door
5.
Switch power off at the mains, the blue light on top of the unit will switch off and the siren noise will stop