4
MEASURES TO BE RESPECTED
Fig. 1
INSTALLATION
1- Provide to fix, temporary, the motor bracket to the pillar until the complete assembly has been
carried out successfully;
2- Brackets must be installed so that the operator, once hinged on them, moves in a horizontal plane;
3- Arrange the installation according to the values of the Fig. 1 and referred table;
4- If different angles have to be referred to then use the following procedure:
4a- temporary fix with two anchor bolts the motor bracket to the pillar centre in such manner that
its edges do not outstand the pillar;
4b- position the motor assembly on the bracket and bolt to it;
4c- install the straight arm, the bent arm and bolt with them;
4d- install the front bracket and bolt to the bent arm;
4e- unlock the rotation of the motor acting on the manual release lock;
4f- move the articulated arm (the angle between the arms must not overcome 178°see Fig. 1)
until the front bracket touch the leaf of the gate in closed position;
4g- tack the position on the leaf;
4h- turn the articulated assembly and the leaf to the maximum open position;
4i- check if the front flange touches the leaf in the previous tacked position;
4l- If the position is different it is needed to shift the anchor point of the motor bracket and repeat
the procedure.
If necessary, it is possible to install the motor internally and let the gate open externally (push to open).
MEASURES OF THE OPERATOR
A (mm) B (mm)
C (mm) D (mm)
160
220
794
445
160
370
750
480
160
480
670
540
160
Max 530
640
580