TECHNICAL FEATURES

QK-S400KIT

QK-S400BKIT

Power supply

230Vac 50Hz

24Vdc

Current absorbed (motor) (A)

1,5

3,5

Power absorbed (W)

340

85

Output speed (r.p.m.)

1,70

1,76

Capacitor (

F)

10

-

Protection rate (IP)
Maximum output torque (Nm)

350

400

Opening time (sec)

14

13

Maximum opening angle (°)
Operating temperature (°C Min/Max)
Thermal protection (°C)

140

-

Work Cycle (%)

60

100

Weight of the motor (kg)
Maximum leaf length  (m)
Maximum leaf weight (kg)

250

300

3,5

110

-30/+70

44

9,5

 

PRE-INSTALLATION CONTROL 

Before installing the automation, you must check that the gate leaf/leaves: 

- can turn without sticking in the ground; 

- does not swing during its movement; 

- is kept in axis by the special hinges; 

- has the stoppers when opening and closing. 

 

Borinato  F.lli  Snc  is  liable  only  for  products  it  manufactures  and  commercializes.  Once 
installed,  the  gate  becomes  a  machine  and  it  is  therefore  subjected  to  the  rules  of  the 
“Machinery  Directive”.  It  is  responsibility  of  the  installer  to  verify its  security. WARNING: 
Borinato  F.lli  Snc  is  not  liable  for  any  damages  to  people,  animals  or  things  due  to 
unauthorised modifications, alterations or betterments on its products by third parties. 

MATERIALS FOR INSTALLATION (For each operator) 

1

2

3

4

5

6

7

                                                                     

 

 

Ref.   

Q,TY 

DESCRIPTION 

STRAIGHT ARM 

BENT ARM 

FRONT BRACKET 

BOLT M14X30 

WASHER ST 14 ISO 

7091 

LOCKING NUT  M14 

MOTOR BRACKET 

Concrete Anchor Bolts 

(not supplied) 

 

Summary of Contents for SPIDER QK-S400KIT

Page 1: ...N G L I S H I T A L I A N O ARTICULATED ARM SWING GATE OPENER AUTOMAZIONE A BRACCIO ARTICOLATO PER CANCELLI A BATTENTE SPIDER manuale d uso e m a n u t e n z i o n e use and mainte n a n c e m a n u a...

Page 2: ...DECLARATION OF COMPLIANCE 7 QUIKO GUARANTEE GENERAL CONDITIONS 8 TECHNICAL FEATURES PRE INSTALLATION CONTROL MATERIALS FOR INSTALLATION MEASURES TO BE RESPECTED MEASURES OF THE OPERATOR USE OF THE CON...

Page 3: ...does not swing during its movement is kept in axis by the special hinges has the stoppers when opening and closing Borinato F lli Snc is liable only for products it manufactures and commercializes On...

Page 4: ...ght arm the bent arm and bolt with them 4d install the front bracket and bolt to the bent arm 4e unlock the rotation of the motor acting on the manual release lock 4f move the articulated arm the angl...

Page 5: ...mmon black wire phase brown wire phase 2 Connect the provided capacitor in parallel with the motor s phases USE OF THE CONNECTORS OF THE MOTORS The motors are supplied with a removable connector see t...

Page 6: ...n the ground 3x Key selector 1x Flashing lamp with aerial 1x Control board and receiver 1x ELECTRICAL CABLES CROSS SECTION Ref Description Cables section mm2 1 Main Power supply 3 x 1 5 2 3 Motor powe...

Page 7: ...has stopped not to let children or animals play near the gate not to let children use the remote control or other operating devices in case of failure to turn off the switch power and operate the gat...

Page 8: ...tirely or partially in a danger zone MINIMUM LEVEL OF PROTECTION FOR THE MAIN EDGE Mode of Use Type of Activation Controls Informed Users private area Informed Users public area Uninformed Users Man o...

Page 9: ...93 68 CE 72 23 CE 92 31 CE and also declares that the related and or specific national technical regulations have been followed EN 12453 EN 12445 on Industrial Commercial and Residential Gates and Doo...

Page 10: ...11 E N G L I S H...

Page 11: ......

Page 12: ...I T A L I A N O manuale d u s o e m a n u t e n z i o n e AUTOMAZIONE A BRACCIO ARTICOLATO PER CANCELLI A BATTENTE SPIDER...

Page 13: ...PER L INSTALLAZIONE MISURE DA RISPETTARE MISURE DELL OPERATORE USO DEI CONNETTORI DEI MOTORI USO DELLO SBLOCCO MANUALE COLLEGAMENTI ELETTRICI AL MOTORE IMPIANTO TIPO SEZIONE DEI CAVI DI COLLEGAMENTO R...

Page 14: ...ante la rotazione Sia tenuta in asse vericale dalle apposite cerniere Sia dotata di arresti in apertura e chiusura Si ricorda che Borinato F lli Snc responsabile solo degli articoli che produce e comm...

Page 15: ...to del motore 4 montare la staffa anteriore sul braccio curvo 5 sbloccare la rotazione del motore ruotando l alberino di sblocco con la chiave ad inserto quadro 6 ruotare I bracci in maniera che formi...

Page 16: ...ndensatore da 10 F Controllare la corretta rotazione del motore e se necessario invertire le fasi del motore USO DEI CONNETTORI DEI MOTORI La morsettiera rimovibile comprende alcuni morsetti I morsett...

Page 17: ...selettore a chiave Un lampeggiante Un quadro di comando Una antenna SEZIONE DEI CAVI DI COLLEGAMENTO Rif Descrizione Sezione del cavo mm2 1 Alimentazione al quadro 3 x 1 5 2 3 Alimentazione motori 4...

Page 18: ...t del cancello non lasciare che bambini usino il telecomando o altri dispositivi di azionamento eseguire una manutenzione periodica in caso di guasto togliere l alimentazione e gestire il cancello man...

Page 19: ...CANCELLI A BATTENTE IN CONFORMIT ALLA DIRETTIVA MACCHINE 98 37 CE E ALLE PARTI APPLICABILI DELLE NORME EN 13241 1 EN 12453 EN 12445 Fig 2 Zone di rischio del cancello a battente figura 2 LEGENDA DEI...

Page 20: ...CE D Lgs 615 96 Direttiva BT 73 23 CE e 93 68 CE D Lgs 626 96 Direttiva Macchine 98 37 CE e direttive 93 68 CE 72 23 CE 92 31 CE inoltre dichiara che sono state applicate le norme armonizzate e o le n...

Page 21: ...11 I T A L I A N O E N G L I S H...

Page 22: ...re ai suoi prodotti 1095 Budapest Mester u 34 Tel 218 5542 215 9771 215 7550 216 7017 216 7018 Fax 218 5542 Mobil 30 940 1970 20 949 2688 1141 Budapest Fogarasi t 77 Tel 220 7940 220 7814 220 7959 220...

Reviews: